14.4 Sensor Data Abbreviations

RGHTCUT
LEFTCUT
CUTRLY (input)
HYDLAT
KNFDWN
PRESET
CUTSOL (output)
AIRSOL
KNLATSOL (output)
CLAMPUP
HYDUP
KNFUP
MTRSTRT (input)
KNFLAT (input)
HYDMOT (output)
AIRMTR
LTLINE (output)
UNLOAD
0
Right Cut Button
0
Left Cut Button
1
Cut Relay
1
Hydraulic Latch Relay
0
Knife Down Proximity Switch
1
Preset Sensor
0
Cut Relay
0
Air Solenoid
0
Knife Latch Solenoid
1
Clamp up Proximity Switch
1
Hyd. Clamp Up Proximity
1
Knife Up Proximity Switch
0
Motor Start Relay
0
Knife Latch Prox.
0
Hydraulic Motor Relay
0
Air Table Motor
1
Line Light Output
0
Unload Valve
14.0 Troubleshooting
Under RHS of table front
Under LHS of table front
On power panel
Main pc board
On bracket attached to knife cylinder
Rear of cutter, under left side of table
Relay below motor contactor
Solenoid valve on top of air motor
Behind display console, on latch
assembly
Rear of cutter, right side of arch
Rear of cutter, at top of clamp cylinder
On bracket attached to knife cylinder
On top of motor contactor block
Behind display console, on latch
assembly
Contactor, top right of main pcb
Behind oil tank
Line light relay on main pcb
Solenoid valve on front of Manifold
65