Installation Instructions - Aga-Rayburn Coalbrookdale Little Wenlock Gas Power Flue Installation And Servicing Instructions

Table of Contents

Advertisement

INTRODUCTION
The Little Wenlock Gas Power Flue (GS1iPF) is factory set
to operate on natural gas or propane (See data label) and
is available with a standard or traditional door option.
Due to newness the stove may give off a slight smell for
a short period after commissioning. This is quite normal
and will disappear after a few hours operation, open
windows and doors if required.
The Little Wenlock Gas Power Flue (GS1iPF) has one
access door as part of its design. The glass fronted door
is for access to the coals and apart from initial
commissioning of the stove, or in case the pilot is
required to be lit with a taper due to malfunction of the
spark ignition system.
UNDER NO CIRCUMSTANCES MUST THE STOVE BE
OPERATED WITH THIS DOOR OPEN OR IF THE GLASS
IS CRACKED OR BROKEN.
The Little Wenlock Gas Power Flue (GS1iPF) has been
designed similar to a solid fuel stove to relevant safety
standards, but during use, many parts of the appliance
can become HOT to touch. We recommend that you
provide and secure a fireguard complying with BS 6539
when the room is used by elderly, infirm or young
persons.
Note: Illustrations show the appliance fitted with the
standard door option.

INSTALLATION INSTRUCTIONS

The installation of the appliance must be in accordance
with the relevant requirements of the Gas Safety
(Installation and Use) Regulations 1995, Building
Regulations and the Building Standards (Scotland)
(Consolidation) Regulations. It should be in accordance
also with any relevant requirements of the local Gas
Region
and
Local
recommendations of the following current British Codes
of Practice & Standards.
BS.6891: Installation of pipes and meters. Low pressure
installation pipes.
BS.5440: Part 1 Flues & Part 2 Air Supply.
BS.5871: Part 1 Installation of Gas Fires, Convector
Heaters, Fire/Back Boilers.
BS.6461: Codes of Practice for factory-made insulated
chimneys for internal application.
BS.8303: Solid fuel appliance flue system.
In your own interests and that of safety to comply with
the law all gas appliances should be installed by
competent persons, (Corgi Registered) in accordance
with the above regulations and with these instructions .
Failure to install the appliance correctly could lead to
prosecution.
NOTE! This stove is fitted with a spillage safety device. In
the event of the flue becoming blocked the fan will
increase to its high speed (indicated by the red light on
the control box) if this fails to clear the blockage the
appliance will shut down.
WARNING: UNDER NO CIRCUMSTANCES IS THE
SPILLAGE MONITORING DEVICE TO BE TAMPERED
WITH. IF PROBLEMS PERSIST SEEK EXPERT ADVICE.
WHEN THE SPILLAGE MONITORING SYSTEM OR ANY
OF ITS PARTS ARE EXCHANGED, ONLY ORIGINAL
PARTS SHALL BE USED.