THE FLUE
The appliances fluing can exist in a number of different
ways depending upon the position of an outside wall and
where the flue outlet is to be positioned.
A
Rear flue outlet directly behind appliance
- supplied as standard Fig. 5.
B
Rear flue outlet with flue running behind wall
- optional Fig. 6.
C
Outlet with flue running in room (MAXIMUM
OF 1 ADDITIONAL BEND) - optional.
UNDER NO CIRCUMSTANCES MUST ADDITIONAL
BENDS OR FLUE PIPE LENGTHS OF OVER 2M BE
USED. THE APPLIANCE CAN ONLY BE INSTALLED
USING THE FLUE PIPE MATERIAL SUPPLIED.
NO FORM OF RESTRICTION CAN BE FITTED TO THE
FLUE SYSTEM.
FLUE TERMINAL
A terminal guard must be fitted irrespective of height of
the installation above ground level Fig. 4.
FLUE LENGTH
THE LENGTH OF THE FLUE, MEASURED FROM THE
CENTRE LINE OF THE FLUE OUTLET TO THE OUTER
FACE OF THE OUTSIDE WALL MUST BE BETWEEN
200MM MINIMUM AND 2M MAXIMUM AND USE NO
MORE THAN 2 BENDS.
FIG. 4
FIG. 5
FIG. 6
DESN. 511189
7
DESN 511297
DESN 511298