THE FLUE
The flue pipe must terminate on an outside wall
observing the minimum clearances in Fig. 3.
Position
A Directly below an openable window,
air vent, or an other ventilation opening
B Below gutter, drain/soil pipe
C Below eaves
D Below a balcony or car port roof
E From vertical drain pipes and soil pipes
F From internal to external corners
G Above adjacent ground, roof or balcony eaves 150
H From surface facing the terminal
I
Facing terminals
J From opening (door/window)
in car port into dwelling
K Vertical from a terminal
L Horizontally from a terminal
Minimum Spacing
mm
300
75
200
200
75
150
600
1200
1200
1500
300
FIG.3
6
DESN511052
DESN511053