Aga-Rayburn Coalbrookdale Little Wenlock Gas Power Flue Installation And Servicing Instructions page 30

Table of Contents

Advertisement

TO LIGHT THE PILOT
Remove the control knob cover. Ensure that the glass
door is closed and locked and that the control knob is in
the OFF (●) position (Fig. 3).
To light the fire ensure the fan is switched on.
See Page 4.
Fully depress the control knob and turn anti-clockwise
(keeping the control knob fully depressed) until the spark
position (
) is reached (Fig. 3). If the pilot has not lit
repeat the operation.
Once the pilot is lit continue to hold in the control knob for
a further 10 - 15 seconds to establish the pilot. When the
control knob is released the pilot should remain alight. If
the pilot fails to remain alight refer to fault finding section
of this document.
If required the pilot may be lit by a long spill or taper as
follows:-
Open the door of the stove (Using the tools supplied, see
Fig. 4) as follows:
1.
Loosen the locking screws with the hex. driver.
2.
Turn the door catch with the tool as illustrated.
Apply a lighted long spill or taper to the pilot (See Fig. 5)
positioned at the front LH side of the burner tray.
Fully depress the control knob and turn anti-clockwise
(keeping the control knob fully depressed) until the spark
position (
) has been reached and the pilot should light.
Once the pilot is lit remove the long spill or taper,
continue to hold the control knob for 10 to 15 seconds to
establish the pilot. When the knob is released, the pilot
should remain alight. If the pilot fails to remain alight,
repeat the procedure, but hold the knob in longer.
When pilot is established close and lock the door
(using the tools supplied).
FIG. 3
FIG. 4
FIG. 5
5
DESN 511305A
DESN 511313

Advertisement