AIR SUPPLY

The stove does not normally require any additional
purpose made ventilation. However, we recommend that
the room has a permanent vent of minimum free air area
of 36cm
.
2
EFFECT OF EXTRACTION FAN
If there is any type of extractor fan fitted in the same
room as the stove, there is a possibility that if adequate
air inlet area from outside is not provided, spillage of the
products from the appliance flue could occur when the
extractor fan is in operation. Where such installations
occur, a spillage test as detailed in BS.5440 Part 1 must
be carried out.

GAS CONNECTION

The complete installation must be tested for soundness
and purged as described in BS.6891.
The gas inlet to the stove is 8mm dia compression, and
providing the distance from the service cock to the stove
does not exceed 1.5m, 8mm dia rigid or semi-rigid supply
pipe may be used.
Above this length, 15mm dia rigid or semi-rigid pipe
should be used.
A service cock must be fitted adjacent to this appliance.

APPLIANCE ASSEMBLY

Unpacking
Remove all parts from inside the pack and ensure that no
damage has occurred during delivery transit. If so, please
contact your local stockist.
Items in Pack:
Instructions-Installation-Servicing-Operating
Coal Guard
Small Coals (12)
Large Coals (8)
Finger Coals (4)
Control Cover
Door Locking Tool
Clay Aggregate
Flue Pipe (1 metre length)
90˚ Flue Bend (1)
Flue Connector (2)
Terminal Guard (2)
Wall Plate

INSTALLING THE APPLIANCE

Position the appliance in accordance with the instructions
given in the section 'LOCATION' and connect the flue
pipe in accordance with the section 'THE FLUE'.
FLEXIBLE PIPE/CONNECTIONS MUST NOT BE USED.
Connect the stove to the gas supply. (See Gas
Connection).
11