System Preparation and Configuration
DS2000 Configuration Guidelines
The total number of components you can install and connect depends on power supply capacity and the Sys-
tem Load Factor. Review the Configuration Guidelines table below and DS2000 Load Factor Calculations
on page 1-3 when configuring your system.
4 Slot Cabinets
Do not install more than 2 16DSTU PCBs under any circumstances.
The first 16DDSTU PCB you install must be in the first slot (CN1).
You can install up to 40 extensions maximum, as follows:
(2) 16DSTU PCBs = 32 digital extensions
(1) 8ASTU PCB = 8 analog extensions
Total = 40 extensions
You can install up to 24 trunks maximum, as follows:
(3) 8ASTU PCBs = 24 analog trunks
Maximum configuration is 48 ports .
The total of all extensions and trunks cannot exceed 48 .
Always use the System Load Factor table to check your system configuration.
8 Slot Cabinets
Do not install more than 2 16DSTU PCBs for each power supply.
The first 16DDSTU PCB you install must be in the first slot (CN1).
You can install up to 96 extensions maximum.
You can install up to 48 trunks maximum.
The total of all extensions and trunks installed cannot exceed 104 .
Maximum configuration is 104 ports.
8 slot cabinets require A series PCBs, as follows:
CPU PCB P/N 80025 A
Power Supply P/N 80005 A
16 DSTU Digital Station PCB P/N 80021 A
8ASTU 8 Port Analog Station PCB P/N 80041 A
4ASTU 4 Port Analog Trunk PCB P/N 80040 A
8ATRU 8 Port Analog Trunk PCB P/N 80011 A
4ATRU 4 Port Analog Trunk PCB P/N 80010 A
Always use the System Load Factor table to check your system configuration.
1-2
Section 1: Installing the Cabinet
DS2000 Configuration Guidelines
DS2000 Hardware Manual