CID 0172 FMI 04

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the
following conditions:
The signal voltage from the intake manifold air
temperature sensor is less than 0.2 Volts DC for
more than eight seconds.
The ECM has been powered for at least two
seconds.
Diagnostic code 0168-01 is not active.
System Response:
If equipped, the diagnostic lamp will flash. The ECM
will log the diagnostic code.
The ECM will use the default value of 70 °C (158°F)
for the intake manifold air temperature. "Voltage
Low" will be displayed next to the status for "Intake
Manifold Air Temperature" on the electronic service
tool.
Possible Performance Effect:
Poor stability
Poor cold running
White smoke
Black smoke
Poor acceleration under load
Troubleshooting:
This fault can be caused by a sensor that is shorted
to ground or a sensor that is internally shorted.
Perform the following diagnostic procedure: "Engine
Temperature Sensor Open or Short Circuit - Test"
Results:
OK – STOP.
This document is printed from SPI². Not for RESALE
i03797372

CID 0190 FMI 08

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the
following conditions:
The ECM detected an intermittent loss of signal
or a complete loss of signal from the primary
speed/timing sensor for 2 seconds.
The engine has been running for more than three
seconds.
System Response:
If equipped, the diagnostic lamp will flash and the
derate lamp will come on. The shutdown lamp may
come on. The diagnostic code will be logged.
The ECM will use the signal from the secondary
speed/timing sensor.
Possible Performance Effect:
The engine will be derated. If the signal from the
secondary speed/timing sensor is also lost, the
engine will shut down.
Troubleshooting:
This diagnostic code will detect a loss of signal from
the primary speed/timing sensor.
Perform the following diagnostic procedure: "Engine
Speed/Timing Sensor Circuit - Test"
Results:
OK – STOP.

CID 0247 FMI 09

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the
following condition:
Another controller has incorrectly stopped
transmitting a J1939 speed request (TSC1)or
another controller has started transmitting a J1939
speed request incorrectly.
85