Cid 0100 Fmi 03; Cid 0100 Fmi 04; Cid 0100 Fmi 10 - Perkins 1106D Troubleshooting Manual

Electric power generation
Table of Contents

Advertisement

KENR6201-01
Troubleshooting:
This diagnostic code indicates that the frequency of a
digital throttle signal is out of the normal range.
Perform the following diagnostic procedure: "Speed
Control (PWM) - Test"
Results:
OK – STOP.

CID 0100 FMI 03

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the
following conditions:
The signal voltage from the engine oil pressure
sensor is greater than 4.95 Volts DC for more than
eight seconds.
The ECM has been powered for at least two
seconds.
The engine is not running or the engine coolant
temperature is greater than 38 °C (100 °F).
System Response:
The ECM will log the diagnostic code. If equipped,
the diagnostic lamp will flash. The ECM will set data
for engine oil pressure to the default value.
Note: The engine oil pressure that is displayed on
the electronic service tool is the default value for
engine oil pressure. The default engine oil pressure
is 600 kPa (87 psi). The electronic service tool
will display "Voltage Above Normal" on the status
screens.
Possible Performance Effect:
None
Troubleshooting:
This diagnostic code can be caused by an open
circuit or a short to another power source.
Perform the following diagnostic procedure: "Engine
Pressure Sensor Open or Short Circuit - Test"
Results:
OK – STOP.
This document is printed from SPI². Not for RESALE

CID 0100 FMI 04

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the
following conditions:
The signal voltage from the engine oil pressure
sensor is less than 0.1 Volts DC for more than
eight seconds.
i03797081
The ECM has been powered for at least two
seconds.
The engine is running.
System Response:
The ECM will log the diagnostic code. If equipped,
the diagnostic lamp will flash. The ECM will set data
for engine oil pressure to the default value. The
electronic service tool will display "Voltage Below
Normal" on the status screens.
Possible Performance Effect:
None
Troubleshooting:
This diagnostic code can be caused by a short to
ground or a shorted sensor.
Perform the following diagnostic procedure: "Engine
Pressure Sensor Open or Short Circuit - Test"
Results:
OK – STOP.

CID 0100 FMI 10

Conditions Which Generate This Code:
The Electronic Control Module (ECM) detects the
following conditions:
No other codes for the oil pressure sensor are
active.
No 0262 diagnostic codes are active for the 5 Volt
supply.
The engine speed is greater than 600 rpm.
81
Troubleshooting Section
i03797131
i03797149

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents