Available languages

Available languages

  • ENGLISH, page 1
Before you start:
Select correct thermostat location
Mounting: to mount thermostat you can use included
accessories (mounting screws). Remove plate from
the back to mount it to the wall. After that just put
thermostat on the plate.
Please note:
The ideal position to thermostat mounting is about 1,5m
under floor level far from heating or cooling sources.
Thermostat can't be exposed to sunlight or any extreme
conditions like for example draft.
M
M

Wiring diagram:

AC 230V
L
N
COM
NO
L
230V~,50Hz
SQ610
S1
S
T
Symbols explanation:
S - volt-free contact
T - temperature sensor
L, N - 230V AC pover supply
COM, NO - Voltage free output
S1,S2 Terminals:
- air or floor temperature sensor
- external volt-free contact to connect any ON/
OFF switch or occupancy sensor (Hotel card)
N
S2
3