Wiring diagram for control box connection:
3
KL08
NSB
Power
L
N
AC 230V
L
N
Please note:
Self-acting SQ610 Quantum Thermostat without application support can be easily added to the
Smart Home app anytime. All settings made before adding to the application are automatically
copied to the Smart Home app.
S1
S2
L
N
COM
NO
L
N
SL
1-8 Zones
Legend:
S
Boiler connection * - Boiler' s contacts
for ON/OFF thermostat (according to the
boiler' s instructions)
Pump
Valve actuator
Heating mat
Boiler
13