Analog Board Led Functions - Hypertherm HySpeed HT2000 Instruction Manual

200 volt plasma arc cutting system
Hide thumbs Also See for HySpeed HT2000:
Table of Contents

Advertisement

MAINTENANCE
Number
of blinks
1
Indicates that the IHS Complete signal has not been returned within 30 seconds after the
plasma START command has been given.
2
Indicates that an "interlock" error has occurred.
3
Indicates that the HOLD input (for multi-torch systems) was not released within 30 seconds
after the end of preflow.
4
Indicates that there was no transfer within 300ms.
5
Indicates that transferred current arc was lost during ramp up.
6
Indicates that the current was lost from chopper #1 (CH1).
7
Indicates that the current was lost from chopper #2 (CH2).
8
Indicates that transferred current arc was lost during ramp down.
9
Indicates that the software has an error.
10
Indicates that the input voltage has dropped below 15% of the nominal value.
Eg: Input voltage for a 480V power supply drops below 408V.

Analog Board LED Functions

D3: +12VDC
D4: Chopper Current CH2
D6: Chopper Current CH1
8-22
22
Figure 8-5
Rec 2
D3
Rec 3
Explanation
Error Codes
D6
D4
Rec 1