rising high
a. Evaporator air flow restriction
11. Evaporator
b. Not stopping due to air leak, high
freezing up
c. Low ambient temperature
d. Bad thermostat or sensor
e. Moisture in the system
f. Refrigerant low or leaking
g. Capillary tube blockage
a. Air leak in wine cellar
12. Water leak
b. Evaporator air flow restriction
c. Water passages restricted
d. Drip tray leak
e. High humidity
a. Incorrect fuse or breaker
13. Circuit
b. Incorrect wirings
tripping
c. Failed components
a. Mounting area not firm
14. Noisy
b. Loose parts
operation
c. Compressor overloaded due to
d. Malfunctioning components
ambient
temperature
setting
high ambient temperatures or
airflow restriction
- 18 -
a. Check for fans & CFM
b. Check
for
or
low
ambient temperature and setting
c. Defrost unit
d. Check for thermostat and sensor
e. Works
initially
service.
f. Call service to check for current and
sealed system leakage
g. Call service to check for capillary
frost
a. Check for any air leak
b. Check air flow or air TD crossing
evaporator
c. Clean the drip tray
d. No water overflow but leak
e. Use drain line
a. Check for proper fuse or breaker
b. Check for wirings and connections
c. Call service
a. Add support to improve installation
b. Check fan blades, bearings, cabinet
washers, tubing contact and loose
screws.
c. Check for airflow blockage
d. Call service for checking internal
loose, inadequate lubrication and
incorrect wirings
seal,
door
opening,
then
stops; Call