Vinotemp WINEMATE WM-2500SSDWC Operation Care Installation Manual
Vinotemp WINEMATE WM-2500SSDWC Operation Care Installation Manual

Vinotemp WINEMATE WM-2500SSDWC Operation Care Installation Manual

Split water-cooled ceiling-mounted cooling system

Advertisement

Quick Links

Split Water-Cooled Ceiling-Mounted Cooling System
Operation Care Installation Manual
Read and save these instructions
Vinotemp International Corp
732 South Racetrack Road, Henderson, NV 89015
Tel: (800) 777-VINO Fax: (310) 886-3310 Email: info@vinotemp.com
WM-2500SSDWC
WM-4500SSDWC
WM-6500SSDWC
WM-8500SSDWC
WM-12000SSDWC
www.vinotemp.com

Advertisement

loading

Summary of Contents for Vinotemp WINEMATE WM-2500SSDWC

  • Page 1 Split Water-Cooled Ceiling-Mounted Cooling System Operation Care Installation Manual WM-2500SSDWC WM-4500SSDWC WM-6500SSDWC WM-8500SSDWC WM-12000SSDWC www.vinotemp.com Read and save these instructions Vinotemp International Corp 732 South Racetrack Road, Henderson, NV 89015 Tel: (800) 777-VINO Fax: (310) 886-3310 Email: info@vinotemp.com...
  • Page 2 Important Safety Information WARNING To avoid the risk of electrical shock, property damage, personal injury, or death: • The power cord must be plugged into a 3-prong grounding type wall receptacle, grounded in accordance with the National Electrical Code, ANSI/NFPA 70 – latest edition and local codes and ordinances. •...
  • Page 3: Table Of Contents

    Table of Contents Cellar Construction Guide Features & Specifications Temperature & Humidity Care Guide User’ Troubleshooting Installer’s Instructions Electrical Wirings Warranty------------------------------------------------------------------ 27...
  • Page 4: Cellar Construction Guide

    Cellar Construction Guide This is only a guide and shall be considered as the minimum requirements. All interior walls, ceilings and floors shall have a vapor barrier and a minimum of R13 insulation. All exterior walls and ceiling shall have a vapor barrier and a minimum of R19 insulation.
  • Page 5: Features & Specifications

    Features and Specifications ï WM-2500~12000SSDWC split water-cooled ceiling-mounted cooling systems are designed to provide a cold environment between 50~65 °F with a humidity range within 50~70% RH for a properly insulated wine cellar. ï These temperature and humidity ranges are optimized for long term storage of wine like that in natural caves.
  • Page 6 CAUTION The condensing unit must operate above 32°F ambient temperature. NOTE The cooling capacity is determined under 55°F cellar temperature, 75°F cellar ambient temperature and 90°F condensing unit ambient temperature, with R13 interior and R19 exterior insulations. Higher ambient temperatures or lower insulations will cause reducing capacity and the cellar temperature may not be maintained at 55°F.
  • Page 7: Temperature & Humidity

    Temperature and Humidity 1. The controller Fig. 2 TEMPERATURE CONTROLLER 1) Keys SET: To display set-point; in programming mode it selects a parameter or confirms an operation. : To start a manual defrost. : To see the maximum stored temperature; in programming mode it browses the parameter codes or increases the displayed value.
  • Page 8 4) Alarm Signals The alarm codes are described as follows. MESSAGE CAUSE FUNCTION Temperature probe Compressor switching to Con and faulty Probe temperature ALU higher than the High temperature setting temperature; Outputs unchanged alarm Probe temperature ALL lower than the Low temperature alarm setting temperature;...
  • Page 9 5. Manual Defrost Press and hold the defrost key until defrost starts. The defrost indicator will be 6. Parameter Programming keys until the “°C” or “°F” LED starts flashing, 1) Press and hold the SET + then release the keys. 2) Press and hold again the SET + keys until the Pr2 label is displayed, then release the keys.
  • Page 10 NOTE Depending on the controller, not all parameters are available.
  • Page 11 7. How to calibrate the air probe If the actual cellar temperature differs from the setting temperature, set parameter ot = actual cellar temperature minus set-point. 8. How to adjust defrost settings In case there is excessive frost, the parameters FnC = C-y, idF = 4 and MdF = 20 can be used to avoid frost.
  • Page 12: Care Guide

    Care Guide In general, always unplug system or disconnect power while doing care. 1. Condenser Water Line Cleaning • To clear any sediment that may accumulate, the water regulating valve may be manually flushed. • Insert screwdrivers under both sides of the valve spring guide and lift upwards to flush.
  • Page 13: User' Troubleshooting

    User’s Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive. Complaint Possible Causes Response 1. Unit not running Power cord not plugged Check power cord No power from supply Check receptacle and fuses Incorrect or loose wirings Check all wirings and connections...
  • Page 14 Dirty Condenser Clean condenser Improper condenser cooling Check for water flow Iced evaporator Defrost and reset temperature Refrigeration system restriction Call service Refrigerant leak Call service Undercharge or overcharge Call service Failed components Call service 7. Unit running a. Improper cellar insulation & seal a.
  • Page 15 14. Excessive a. Air leak in the wine cellar a. Check for any air leak condensate causing excessive condensate b. High humidity causing b. Use drain line excessive wine cellar -14-...
  • Page 16 condensate c. Drain restricted c. Clean the drip tray and drain line 15. Condensate Drain line restricted Check for drain inside ducts Continually running not raise temperature setting stopping or increase defrost Increase flow raise Too cold supply air temperature setting Duct not insulated Check for insulation Condensate...
  • Page 17: Installer's Instructions

    WINE~MATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed the system. Proper installation is critical. Vinotemp can only warrant the quality of the components. The installation and proper operation of the system must be warranted by the installer.
  • Page 18 Parts not included: Liquid line copper tubing Suction line copper tubing Water lines Liquid and suction line locations may differ from that they are shown CAUTION below, please check on the units for proper installations. To prepare rough-in, leave minimum 4” clearances for electrical NOTE wiring and refrigeration piping.
  • Page 19 Fig. 3 Temperature Controller (4.5”L X 4.5”W X 3.75H) -18-...
  • Page 20 Fig. 4 WM-25~45SFCD Evaporator Unit Fig. 5 WM-65~120SFCD Evaporator Unit -19-...
  • Page 21 Fig. 6 WM-250~WM-1203SCUR-WC Condensing Unit Fig. 7 WM-Liquid Filter Fig. 8 WM-Liquid Indicator 2. Temperature Controller and Air Probe Location 1) The temperature controller can be mounted either inside or outside the wine cellar, but the air probe must be located inside. 2) The air probe shall be located in the wine cellar 5 ft above the floor or the air return area, but it shall not be located in the air supply area or other areas where air is not circulated.
  • Page 22 may be recessed in the ceiling with short curved rectangular ducts in air supply, but the air flow CFM must be checked. 2) For a direct blow application, air supply shall be unobstructed minimum 12”. For a deflector application, leave 2” clearance for air supply. Air return shall be unobstructed minimum 6”.
  • Page 23 1) The piping starts from ➔ condensing unit’s receiver discharge valve ➔ liquid filter ➔ liquid indicator ➔ liquid line ➔ to evaporator unit’s liquid line connection (assembled with solenoid valve and expansion valve) ➔ suction line connection ➔ insulated suction line ➔ to condensing unit’s suction valve. 2) If the line set exceeds 75 ft long, use both inverted U trap and suction accumulator to prevent liquid from flooding back to the compressor.
  • Page 24 BACK POSITION FRONT POSITION MIDDLE POSITION Fig. 9 ROTALOCK Valve Operation BACK POSITION FRONT POSITION MIDDLE POSITION Fig. 10 Base Valve Operation Back Position: Normal operation, manifold port is closed. Front Position: Storage operation, liquid or suction line connection is closed. Middle Position: Installation operation, all ports are open.
  • Page 25 9) Check the following temperatures and pressures. 9. Adjusting and Completing the Installation 1) Set the water regulating valve opening set-point at refrigerant pressure of 120 PSIG. Turn counterclockwise to raise the operating set-point. Fig. 11 Water Regulating Valve 2) Checking pressure control settings Suction pressure setting: Cut out=5 psig;...
  • Page 26 (located on the side or front) clockwise to decrease the minimum speed or counter-clockwise to increase the minimum speed. The minimum speed should be adjusted until it supplies the required CFM. Fig. 13 Fan Speed Control 4) The subcooling at the condensing unit shall be around 10°F. The charge may be complete when there are no more bubbles forming in the liquid indicator.
  • Page 27 11) Turn both discharge and suction valves in the back positions. 12)Disconnect the manifold. 10. Pressure, Superheat and Subcooling Readings To read properly, the service valves must be in the middle CAUTION positions. Complai Possible Causes 1) Compressor may be bad 1) High suction pressure and low head pressure Zero superheat and zero subcooling...
  • Page 28 High superheat and normal subcooling Low suction pressure and high Both evaporator head pressure condenser restricted; High superheat and high subcooling liquid and suction lines connected wrong suction pressure and high head Liquid line restricted pressure before receiver High superheat and high subcooling Condenser restricted low to normal suction pressure and high head pressure...
  • Page 29 Electrical Wiring Diagrams Hidden lines are the field wirings CAUTION Use minimum 14 gauge wires for power lines. If equipped with low ambient condition kit, use low ambient temperature wiring diagrams. A safety switch is always recommended for the condensing unit. Fig.
  • Page 30 Fig. 16 WM-6500~12000SSDWC Electrical Wiring Diagram -29-...
  • Page 31: Warranty

    BTU/H. While every effort has been made to provide accurate guidelines, VINOTEMP can not warranty its units to cool a particular enclosure. In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty.
  • Page 32 VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.