When there is a water leak
Place where the water leaks
Area where the bypass
selector is connected
Area where the water supply
hose is connected
Area where the outlet pipe
is connected
Top of the unit
Bottom of the unit
Faucet area

Optional Accessories

Obtain all optional accessories from your dealer.
For details on how they are used, refer to the accompanying instructions.
Consumables
Replacement cartridge
Model No.: TK-AS45C1-EX
Model No.:
P-A3303ZEX
Used when
mounting the unit
on a wall
TK-AS66-ZEX̲En.indb   49
TK-AS66-ZEX̲En.indb   49
Check following point
 Has the bypass selector been installed on the faucet securely?
 If not, install it securely.
 Have the parts inside the bypass selector been inserted
properly?
 If not, insert them properly.
 Has the water supply hose been connected securely to the
bypass selector?
 Insert the hose as far as it will go, and tighten it using the
hose fastening nut.
 Has the outlet pipe been connected to the unit securely?
 If not, screw it in securely until it will go no further.
 Did you install the gasket? Or is the gasket twisted?
 Install the gasket properly.
 Has the cap been installed securely on the unit?
 Has the cartridge been installed securely?
 If not, install it securely.
 Depending on the temperature and humidity conditions, water
formed from condensation may collect inside the unit.
(This is not a malfunction.)
 Is the faucet gasket old?
 Call in a plumber.
 Is the faucet (insulating cap, etc.) cracked?
 Call in a plumber.
For use with large faucet
Large-diameter Faucet Fitting (inside diameter 32.5 mm)
Model No.: P-06JRC
 For faucets whose end diameter is 24 ~ 32 mm
Wall mounting bracket
CAUTION
 If you want to install the unit on a wall, ask an authorised
dealer or service personnel to do the job.
Installing the unit yourself may cause the unit to fall and result in an accident.
 The location where the unit is to be installed must be able
to support a weight of over 6 kg.
If the installation location does not have enough strength to
support the unit, the Alkaline Ionizer may fall, resulting in an
accident and kitchen damage.