Panasonic TK-AS700 Operating Instructions Manual

Hide thumbs Also See for TK-AS700:

Advertisement

Quick Links

Thank you for purchasing this Panasonic product.
感謝您購買 Panasonic 的產品。
 Please read these instructions carefully before using this product, and
save this manual for future use.
 Please carefully read the "Safety Precautions" (P. EN4 ~ EN8)
of this manual before use.
 Be absolutely sure to check that the purchase date has been entered on
the warranty.
 Please keep in mind that the manufacturer of the product will not be
responsible for any product malfunctioning or accidents resulting from
the improper installation or operation of the product.
 請在使用本產品之前仔細閱讀本說明書, 並妥善保管本說明書以備日後使用。
 請在使用之前仔細閱讀「安全注意事項」 (TC4~TC8頁) 。
 保證書上的「購買日期」請務必填寫。
 因安裝錯誤或不正確使用, 而造成產品故障或發生事故時, 本公司恕不負責。
Use properly to economize on electricity
TK-AS700_En.indb
TK-AS700_En.indb
1
1
Operating Instructions
Alkaline Ionizer
Model No.
We use NSF42 certifi ed
activated carbon.
我們使用 NSF42 認證的活性碳.
Activated carbon (APG-05TGA
60/200) manufactured by
Kuraray Co.,Ltd. used in this
product is Tested and Certifi ed
by NSF International against
NSF/ANSI Standard 42 for
material requirements only.
(Check Date (2022. 6. 1))
本產品使用的活性碳由 Kuraray
Co.,Ltd. 製造的(APG-05TGA
60/200 ) 物料需求由 NSF 國際通
過 NSF/ANSI Standard 42 檢測
和認證。
正確使用, 節省用電
(檢查日期(2022年6月1日) )
使用說明書
For Household Use
電解水機
家庭用
TK-AS700
COMPONENT / 成分
2022/06/23
2022/06/23
14:07:30
14:07:30

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic TK-AS700

  • Page 1 電解水機 家庭用 TK-AS700 Model No. We use NSF42 certifi ed Thank you for purchasing this Panasonic product. activated carbon. 感謝您購買 Panasonic 的產品。 我們使用 NSF42 認證的活性碳.  Please read these instructions carefully before using this product, and save this manual for future use.
  • Page 2 Use Alkaline Ionizer Removing substances • Free residual chlorine • Bromoform • 1,2-DCE • Turbidity • Tetrachloroethylene • Benzene • Chloroform • Trichloroethylene • Geosmin (mold smell) • Total trihalomethane • CAT (pesticide) • Phenols • Bromodichloromethane • 2-MIB (mold smell) •...
  • Page 3: Table Of Contents

    Contents Safety Precautions Operating Precautions EN10 Names of the Parts and Steps to Take Before Operation Steps to take before operation EN12 EN13 Installation 1 Check the main unit and supplied accessories EN14 Installation 2 Checking the faucet EN15 Installation 3 Attaching the bypass selector EN18 Installation 4...
  • Page 4: Safety Precautions

     If the Alkaline Ionizer falls into water by accident, disconnect its power plug from the power outlet, and take the Alkaline Ionizer out of the water. (Otherwise it may cause an electric shock.) → Please contact a dealer or subordinate service station of Panasonic for inspection or maintenance. TK-AS700_En.indb TK-AS700_En.indb...
  • Page 5 (Doing so can lead to a fi re and/or electric shocks.) <Examples of abnormality and fault> → Please contact a dealer or subordinate • H34 is displayed on LCD service station of Panasonic for inspection • Abnormal sound during operation or maintenance. • Abnormal heat or deformation of the ...
  • Page 6 Safety Precautions Please make sure to follow these instructions CAUTION Installation location  Do not block the main spout or bend, twist, fl atten, pull or clamp the hose. (Doing so may cause water to leak, prevent the output of water or cause other malfunctioning.) ...
  • Page 7 CAUTION About the application of alkaline ion water, weak acidic water, and acidic water that cannot be drunk or used  Do not drink the following kinds of water.  Weak acidic water or acidic water  Water which comes out of the drain hose ...
  • Page 8 Safety Precautions Please make sure to follow these instructions CAUTION Accidental ingestion Maintenance  Do not leave the supplied  Do not splash water or wash the accessories within reach of main unit. infants or toddlers. ( Doing so may cause an electric shock or malfunction.) ( Doing so may result in accessories being swallowed by mistake.)
  • Page 9: Operating Precautions

    Operating Precautions Water supply Usage  Do not drink water in case of the following  Do not place this product upside down. conditions. (Doing so may cause that lead to malfunction.)  The table below shows the temperatures of water Water which is very turbid, or water containing a ...
  • Page 10: Names Of The Parts And Steps To Take Before Operation

    Names of the Parts and Steps to Take Before Operation Main unit Water supply hose Outlet pipe Faucet Power plug Hose strap Main spout Power cord Suction disc Drain hose Cartridge (P. EN29~EN30) Bypass selector When using alkaline ion water, etc. When using tap water Water is fed to the main unit, and the The water comes out from the source water...
  • Page 11 Control panel Display (LCD display)  Displays the remaining amount Hydrogen concentration (guideline) of water fl ow Displays a guideline of  until cartridge hydrogen concentration only replacement. for alkaline ion water. (P. EN29) * This is an estimate calculated from electrolysis conditions.
  • Page 12: Steps To Take Before Operation

    Steps to take before operation Check the main Installation 1 unit and supplied P. EN13 accessories Checking Installation 2 P. EN14 the faucet Attaching the Installation 3 bypass selector P. EN15 The attaching method P. EN17 diff ers depending on the shape of faucet.
  • Page 13: Installation 1 Check The Main Unit And Supplied Accessories

    Check the main unit and supplied accessories Installation 1 If any are missing, contact your dealer. Items in the package Main unit Bypass selector   Spring Power cord Cartridge (length: approx. 3 m) (Consumables) Drain hose (With spring / length: approx. 60 cm) Water supply hose (No spring / length: approx.
  • Page 14: Installation 2

    Checking the Faucet Installation 2 Water faucet which cannot install the Alkaline Ionizer Faucet without a metal lip end Plastic or other material Faucet with an end of 10 mm or less 10 mm or less Shower nozzle Faucet with sensor Note Faucet with a fl...
  • Page 15: Installation 3

    Attaching the bypass selector Installation 3 Keep all parts that are not used during installation, as they may be needed later if the unit is moved or the faucet is changed. Outside-screwed faucet • Water faucet which can attach the Alkaline Ionizer without an accessory.
  • Page 16: Installation 3

    Attaching the bypass selector (continued) Installation 3 Keep all parts that are not used during installation, as they may be needed later if the unit is moved or the faucet is changed. Inside-screwed faucet • Water faucet which can attach the Alkaline Ionizer with an accessory.
  • Page 17 Keep all parts that are not used during installation, as they may be needed later if the unit is moved or the faucet is changed. Faucet without an aerator • Water faucet which can attach the  more than 10 mm Alkaline Ionizer with accessory.
  • Page 18: Installation 4

    Installing the Alkaline Ionizer Installation 4 Gasket Choose a stable, level surface. 10 cm or more 18 cm or more Extend the power cord and hose in the manner that best suits the location where the unit is installed.  Do not fl atten or bend the cord or hose. When extending the cord and When extending the cord and Bottom of the unit...
  • Page 19 After completing the preparations, connect the water supply hose.  Remove the hose fastening nut from the bypass selector, and pass the hose through the nut.  Insert the water supply hose into the bypass selector as far as it will go. <OK>...
  • Page 20 Checks after installation Installation 5 After installation, check the following items. In the case of abnormality, refer to the actions to be taken for each part. Reference Check item Trouble inspection location and remedial action page Is water coming out of the ...
  • Page 21 Reference Check item Trouble inspection location and remedial action page Is there any water leaking  Has the water supply hose been attached EN19 from where the water supply securely to the bypass selector? hose is connected? → Insert it as far as it will go, and use the hose fastening nut to secure it.
  • Page 22 Measure and adjust the pH level of water Installation 6 After the Alkaline Ionizer has been installed or after it has not been used for a prolonged period (generally, a week or more), be absolutely sure to measure the pH level, and check that it is within the “pH standard” before using the Alkaline Ionizer. Remember to measure the pH level periodically (at least once a month).
  • Page 23 When is adjustment necessary? When the measurement results are beyond the range of “pH level standardˮ, adjustment shall be made. After the completion of adjustment, the pH level shall be measured again. When the pH level of the Alkaline 3 or No adjustment weak acidic water is within the range required.
  • Page 24: Usage Of Water

    Usage of Water Weak Alkaline ion water Acidic Purifi ed acidic water water water Alkaline 1 Alkaline 2 Alkaline 3 Alkaline 4 Taking Drinking water in daily life medicine Approx. 0.5 to 1 liter a day Non-drinkable Non-drinkable Get used to First-time drinking drinking...
  • Page 25 Convenient usage Weak Alkaline ion water Acidic Purifi ed acidic water water water Alkaline 1 Alkaline 2 Alkaline 3 Alkaline 4 Washing Making baby Cooking and Removing astringency, Washing boiling vegetables the face formula making tea For removing For tea and When removing tea stains from boiled food...
  • Page 26: How To Use

    How to Use Water temperature under 35 °C Measure the pH once a month Measure the pH once a month periodically or when When is used, water does not the product is not used for one week or more. come out from the drain hose. (P.
  • Page 27 When the screen in step 5 is displayed or the When disappears and the  water quality signal shows the waveform, following screen is displayed while water is fl owing use water. PiPiPi Those screens are displayed when the faucet is not opened enough or the amount of water fl...
  • Page 28: Maintenance

    Maintenance Important  Do not use detergents, cleansers, paint thinners, benzine, alcohol or kerosene for cleaning purposes. If, for instance, a detergent has been used by mistake, wipe the surface with a damp cloth to remove all traces of the detergent. ( Otherwise, the detergent may get mixed in with the water running through the Alkaline Ionizer or the plated parts may be damaged or peel off...
  • Page 29: Replacing The Cartridge

    Replacing the Cartridge Replacement cartridge When the service life of the cartridge is to be expired or the purifi ed Model No: TK-AS700C-EX water ability is reduced, please replace the cartridge with a new one. (P. EN41) Cartridge replacement standard There are 3 kinds of change standards.
  • Page 30 Replacing the Cartridge (continued) Replacing method  Do not tip over the main unit, or face up the main spout. (Water may enter the inside of the main unit, resulting in a malfunction.)  Since the cartridge usage amount needs to be reset, do not remove the power plug when replacing the cartridge.
  • Page 31: Automatic Electrode Cleaning

    Automatic Electrode Cleaning Automatic electrode cleaning is performed to remove calcium deposited on the electrode plate Wait for a while.  Do not remove the power plug.  Water coming out of the main spout and drain hose during automatic electrode cleaning cannot be used.
  • Page 32: Changing The Settings

    Changing the Settings How to change The settings can be changed according to the usage. (This operation is not available while water is fl owing or during automatic electrode cleaning.) Pressing the water quality selector buttons during operation returns to the main screen. (P. EN11) Preparation : Turn off...
  • Page 33: When The Power Or Water Supply Is Cut Off

    When the Power or Water Supply is Cut Off When the power supply is cut off (The breaker has operated, or the power  plug is removed.)  Turn off the faucet if the power is cut off while the Alkaline Ionizer is being used. ...
  • Page 34: When Moving The Alkaline Ionizer

    When Moving the Alkaline Ionizer Remove water from the main unit with the following steps before moving the product.  Stand the main unit while moving. After removing the water, a small amount of water may remain, so put the main unit in a bag, etc.
  • Page 35: Q&A

    Q&A Question Answer What is the part number of the TK-AS700C-EX (P. EN41) cartridge for replacement? For usage, we have confi rmed a removal capacity of 6 000 liters by Is it possible to use the running water. The cartridge cannot be used beyond the amount. cartridge exceeding (Depending on the water quality, it may not be used even less than 6 000 liters.) the amount of 6 000...
  • Page 36 Q&A (continued) Question Answer Use it within 1 day at room temperature. How long do the When alkaline ion water is produced, the chlorine (sterilizer) in the tap water is alkaline ion water removed off , making it easier for bacteria to proliferate. and purifi...
  • Page 37 Question Answer The type of water diff ers depending on the water coming out from the main spout. What kind of water • It is acidic water if alkaline ion water is coming out from the main spout. is the one coming •...
  • Page 38: Before Requesting A Repair Service

    Before Requesting a Repair Service First, check P. EN38 to P. EN40. If the problem is not solved after the following contents are checked Disconnect the power plug, and contact the dealer where you purchased the product.  Disconnecting the power plug once and inserting it again after approx. fi ve seconds may restore the product to the normal state.
  • Page 39 Problem Check point Faucet and connection parts of bypass selector, water  See P. EN20~EN21. supply hose, and outlet pipe Bypass selector  The cause seems to be calcium, etc. depositing inside the bypass (location other than the selector. water outlet selected with →...
  • Page 40 Before Requesting a Repair Service (continued) Problem Check point Water is drained  Water inside the main unit is drained every after use. even after the faucet (P. EN27, EN31) is closed.  Is the drain hose bent or fl attened? Water is not drained •...
  • Page 41: Optional Accessories

    Optional Accessories Obtain all optional accessories from your dealer. For details on how they are used, refer to the accompanying instructions. Consumables For use with large faucet Replacement cartridge Large-diameter Faucet Fitting Model No : TK-AS700C-EX (inside diameter 32.5 mm) Model No : WTK7205X7378 ...
  • Page 42: Specifi Cations

    Specifi cations Rated voltage, frequency, input current 220-240 V ~ , 50 Hz, 0.65 A Rated power consumption Approx. 130 W (approx. 1 W during standby) Approx. 180(W) × 115(D) × 328(H) mm Dimensions Main unit (Depth including LCD display: 123 mm) Approx.
  • Page 43 Memo EN43 TK-AS700_En.indb TK-AS700_En.indb 2022/06/23 2022/06/23 14:08:08 14:08:08...
  • Page 44 • 就算已將電源插頭插入 ,仍沒 出現以上現象時,請停止使用, 有任何顯示出現 避免故障或事故發生。從插座 • 出現異常顯示(U21 ~ U28) , 是否有這樣的 拔下電源插頭, 務必委託經銷 現象? 即使處理異常顯示依舊出現 商或Panasonic直屬服務站人 • 出現異常顯示(H31 ~ H39) 員檢查。 • 出現其他異常現象或故障 Panasonic Corporation https://www.panasonic.com ZGS0TKAS700EXZ © Panasonic Corporation 2022 H1022-0 Printed in Japan TK-AS700_En.indb TK-AS700_En.indb 2022/06/23 2022/06/23 14:08:08 14:08:08...

Table of Contents