Troubleshooting (continued)
When the LCD display shows the following: (continued)
Symptom
"Replace cartridge and
press switch display for
about 3 seconds." message
appears on the display
The "U25" or "U26" code is
not cleared even after the
cartridge is replaced
The "U26" code does
not appear even after
the time (approx. 1 year)
representing the guideline
for when to replace the
cartridge has passed
Is this a malfunction?
Symptom
Water comes out after
the faucet has been
turned off
No water comes out
from the acidic water
spout when using
other than purifi ed
water
No water comes out
when the Alkaline
Ionizer is used at the
"Alkaline" or "Alkaline
4 (Strongly Alkaline)"
setting
Water is leaking from
a place other than the
selected spout
EN46
TK-AS66-ZEX̲En.indb   46
TK-AS66-ZEX̲En.indb   46
Check following point
 The fl ow has diminished because of cartridge clogging or some
other reason.
 Disconnect the power plug and then re-connect it. If
operation is continued and the "U25" code appears, replace
the cartridge.
 Have you forgotten to reset the cartridge life?
 Refer to step 3 in the procedure of "Replacing the cartridge",
and reset the cartridge life.
 Did you reset the cartridge life with the power plug
disconnected?
 Connect the power plug, and then reset the cartridge life.
 Has the Alkaline Ionizer seen less use so that the total
run-through volume of water serving as the guideline for
cartridge replacement (12 000 liters) has not been reached
yet?
(This is not a malfunction. Check the cartridge life display.)
 Although the fi ltering performance is still satisfactory, the
cartridge's activated carbon may deteriorate rapidly due to
changes in the water quality or other factors so replace it
after using it for a year.
Check following point
 The water inside the outlet pipe is draining off .
 Are the acidic water and drain hoses bent or fl attened?
If water keeps running, it may cause malfunction. Also It can
not electrolysis correctly.
 Has the "Reduce fl ow" appeared on the LCD display?
 Reduce the water fl ow at the faucet slowly until the message
is cleared.
 Are the acidic water and drain hoses bent or fl attened?
 Straighten out the hoses.
 Have the acidic water and drain hoses been connected
correctly?
 Check the connection of the hoses to the acidic water stand.
 Has the "Reduce fl ow" appeared on the LCD display?
 Reduce the water fl ow at the faucet slowly until the message
is cleared.
 The build-up of calcium or other minerals inside the bypass
selector may be to blame.
 Obtain some citric acid from a pharmacy, dissolve 50 g in
one liter of water, and after immersing the bypass selector in
the solution for about 12 hours, rinse with water.
Reference
page
EN35
EN37
EN35
~
EN36
Reference
page
EN21
EN13
~
EN15
EN22
EN13
~
EN15