• Use only Neutrik PowerCON TRUE1 cable connectors for AC mains power input at
the fixture's Mains IN connector and for relaying AC mains power from one fixture's
Mains OUT (Thru) connector to another fixture's Mains IN connector.
• Use minimum 14 AWG or 1.5 mm
16 A-rated and temperature-rated to suit the application. In the USA and Canada
the cables must be UL-listed, type SJT or equivalent. In the EU the cables must be
type H05VV-F or equivalent.
• Do not connect devices to power in a chain if the total maximum current draw of all
the devices in the chain when added together will exceed the current rating of any
cable or connector used at any point in the chain. The supplied power input cable
is rated as follows:
- US power cable: 16 A, 14 AWG, UL-listed, E304117, SJT, 4.9 ft.
- EU power cable: 16 A, 1.5 mm², H05VVF-F, 1.5 m.
Do not connect more than two (2) FR 10 Bar fixtures to power linked together at 100-
120 V, 60 Hz.
Do not connect more than four (4) FR 10 Bar fixtures to power linked together in a
chain at 200-240 V, 50 Hz.
• The voltage and frequency at the Mains OUT socket are the same as the voltage
and frequency applied to the Mains IN socket. Only connect devices to the Mains
OUT socket that accept this voltage and frequency.
• Replace the fuse with a new fuse of the same type and rating only.

Fire safety and protection from burns

• Do not operate the fixture if the ambient temperature (Ta) exceeds 45° C (113° F).
• The surface of the fixture can become hot during operation. Avoid contact by
persons and materials. Do not install the fixture in a location where there is a risk of
accidental contact. Allow the fixture to cool for at least 20 minutes before handling
• Keep the fixture well away from flammable materials.
• Keep all combustible materials (e.g. fabric, wood, paper) at least 0.2 m (8 in.) away
from the fixture.
• Ensure that there is free and unobstructed airflow around the fixture.
• Do not illuminate surfaces within 0.2 m / 8 in. of the fixture. The light output from the
fixture is powerful enough to cause burns or fire in illuminated objects at very close
range.
• Do not place any optical components other than impression FR 10 Bar accessories
from GLP onto the front of the fixture.
• Do not stick filters, masks or other materials onto the fixture. Do not block the light
output in any way. The front surface becomes hot during operation and can melt or
ignite objects that are in contact with the surface. Ensure that the front surface Is
6