Calculating data volumes

General

When using Fronius system monitoring, data is collated that must be transmitted over
the internet.
The data volume must be calculated so that the correct internet connection is selected.
The data volume calculation below provides an overview of the data quantities involved
when using Fronius system monitoring.
Calculating data
The data volume calculation depends on the number of connected devices in the system
volumes
monitoring.
The table below provides an overview of the data volume for various configurations and
time settings (INV = Fronius Symo Hybrid, SM = Smart Meter, BAT = battery module of
the Fronius Solar Battery)
Data volume per day:
Sent
Hourly
(06:00 - 20:00)
Daily
70
Configuration
INV
INV + SM
INV + SM + 3x BAT
INV + SM + 4x BAT
INV + SM + 5x BAT
INV + SM + 6x BAT
INV + SM + 7x BAT
INV + SM + 8x BAT
INV
INV + SM
INV + SM + 3x BAT
INV + SM + 4x BAT
INV + SM + 5x BAT
INV + SM + 6x BAT
INV + SM + 7x BAT
INV + SM + 8x BAT
5 min logging
30 min logging
436 kB
659 kB
2198 kB
2556 kB
2958 kB
3306 kB
3485 kB
4160 kB
30 kB
55 kB
228 kB
262 kB
305 kB
344 kB
388 kB
426 kB
305 kB
349 kB
605 kB
659 kB
750 kB
775 kB
838 kB
920 kB
15 kB
20 kB
49 kB
53 kB
63 kB
68 kB
73 kB
83 kB