Leds; Table 4-1 Definitions Of Pin On The Db9 Female Socket; Table 4-2 Leds On The Rc3000E-Up-Opt-Fe2E1 - Raisecom RC3000E Product Description

Table of Contents

Advertisement

Raisecom
RC3000E (P100R001) Product Description

Table 4-1 Definitions of PIN on the DB9 female socket

1
6
2
7
3
8
4
9
5

4.4.4 LEDs

Table 4-2 lists the LEDs on the RC3000E-UP-OPT-FE2E1.

Table 4-2 LEDs on the RC3000E-UP-OPT-FE2E1

1
2
3
4
PIN
IN1+
IN1-
OUT1+
OUT1-
IN2+
IN2-
OUT2+
OUT2-
When the interface impedance is 120 Ω, use the CBL-E1-DB9M/2RJ45-2.5m
cable to connect the RC3000E to the RJ45 head.
When the interface impedance is 75 Ω, use the CBL-E1-DB9M/4BNCF-2.5m
cable to connect the RC3000E to the BNC female interface.
When the interface impedance is 75 Ω, "+" in the table refers to the core of the
coaxial cable. "-" refers to the metallic shield (GND) of the cable.
No.
Description Status
SYS
ALM
LLOS
RLOS
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
Definition
Green
System working LED
Blinking green: the system is working properly.
Green: the system is working improperly.
Off: the system is working improperly.
Red
General alarm LED
Red: some alarm is generated.
Off: no alarm is generated.
Red
Local line Loss Of Signal (LOS) alarm LED
Red: some signal on the local line is lost.
Off: no signal on the local line is lost.
Red
Remote line LOS alarm LED
Red: some signal on the remote line is lost.
Off: no signal on the remote line is lost.
Description
1 (RX1)
2 (TX1)
3 (RX2)
4 (TX2)
Description
4 Cards
22