INSTALLATION

Maintenance

16. Maintenance
WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
Draining the appliance
The appliance can be drained for maintenance work.
WARNING Burns
Hot water may escape when you drain the appliance.
f Close the shut-off valve in the cold water inlet line.
f
f Open all draw-off valves.
f
f Undo the pipe connections from the appliance.
f
f Store the dismantled appliance in a room free from the risk
f
of frost, as water residues remaining inside the appliance can
freeze and cause damage.
Cleaning the strainer
If dirty, clean the strainer in the threaded cold water fitting. Close
the shut-off valve in the cold water inlet line before removing,
cleaning and refitting the strainer.
1
1 Plastic profile washer
2 Strainer
f Remove the plastic profile washer.
f
f Remove the strainer and clean the components.
f
f Fit the strainer and the plastic profile washer.
f
www.stiebel-eltron.com
2

17. Specification

17.1 Dimensions and connections

225
140
30
100
c06
b02 Entry electrical cables I Installation on unfinished
walls
c01
Cold water inlet
Male thread
c06
DHW outlet
Male thread
Alternative connection options
b03
b04
b04
b02 Entry electrical cables I Installation on unfinished
walls
b03 Entry electrical cables II Installation on unfinished
walls
b04 Entry electrical cables III Installation on finished walls
≤ 20
105
b02
35
116
c01
DHB-E LCD AU
b04
20
b02
b04
30
165
b04
DHB-E LCD AU
DHB-E LCD AU|
G 1/2 A
G 1/2 A
17

Hide quick links: