INSTALLATION
Installation
If the flow rate is too low, remove the flow limiter. To do this,
remove the function module from the appliance back panel.
2.
3.
4.
f Release the locking hook.
f
f Push the function module in the appliance back panel slightly
f
towards the back.
f Remove the function module from the appliance back panel
f
by pulling it slightly forwards and lifting it off.
5
1.
4
5.
1 Flow limiter
2 O-ring
3 Cold water pipe bend with recess for locking clip
4 Locking clip
5 Heater
f Remove the cold water pipe bend and the O-ring.
f
10
| DHB-E LCD AU
1.
3.
2.
1
2 3
4.
f Remove the flow limiter from the cold water inlet of the heat-
f
er using a pointed object or suitable pliers.
f Refit the cold water pipe bend and the O-ring.
f
Material losses
!
The O-ring must be fitted to prevent the appliance from
leaking.
f As part of installation, check that the O-ring is in
f
place.
f Secure the cold water pipe bend with the locking clip.
f
Material losses
!
Ensure that the locking clip is located behind the recess
in the pipe bend and fixes the bend in position.
f Mount the function module in reverse order in the appliance
f
back panel until the function module clicks into place.
Installing the appliance
Note
If you are installing the appliance with flexible pipe con-
nections, also secure the bottom of the back panel with
a screw.
1 Cable entry installation aid
2 Cable grommet
Use the installation aid for easier wiring access through the cable
grommet (see plastic parts set supplied).
f Remove the cable grommet from the back panel.
f
f Pull the cable grommet over the cable sheath of the power
f
cable. For large cable cross-sections, enlarge the hole in the
cable grommet if necessary.
f Remove the transport protection plugs from the appliance
f
pipe connections.
1
2
www.stiebel-eltron.com