DSC PowerSeries Neo 3G2080E Installation Manual page 9

Cellular alarm communicator, internet and hspa dual-path alarm communicator, internet alarm communicator
Hide thumbs Also See for PowerSeries Neo 3G2080E:
Table of Contents

Advertisement

HS2016/2032/2064/2128
UA621
5
AC AC
AUX+
Item
Description
1 To External Antenna
AUDIO/DEFAULT
2
Jumper pins 4 and 5 to reset
3 Network Link - Yellow
From NID use only CAT5 supervised
4
maximum cable length 100m (328 feet)
5 RS-232 to third party device
6 RED Wire
5. Install the RS-232 connections (R models only). If using the communicator with a 3rd party device, wire the connections
as per the table below:
6. Perform the following steps for initial power on of the panel with communicator installed:
a. Reconnect the AC power, telephone line, and battery + connector to the panel.
(The communicator and panel will power up together).
b. Observe that the communicator's red and yellow LEDs are flashing together while it initializes. The red and yellow
LEDs will continue to flash until the communicator has successfully communicated to all programmed receivers. If this
is the first time the communicator has been powered up in the panel, the module will initiate communication to C24
Communications to request remote programming.
Figure 3: Communicator Wiring Diagram
PCLINK_2
PGM1
PGM3
Z1 COM Z2 Z3 COM Z4 Z5 COM
PGM2
PGM4
Table 3: RS-232 Connections
3rd Party Device Communicator
TX
Unused
RX
Unused
GND
1
L
SIM
o
3G Radio
c
k
TL2803G(R)E
UA685
3G2080(R)E
TL280(R)E
6
PC-LINK
Z6 Z7 COM Z8
RING
TIP
T-1
R-1
Input Ratings:
+10.8V ~ +12.5VDC
l
90mA(3G2080(R)E) / 120mA(TL2803G(R)E) standby;
l
400mA alarm
l
Control Panel minimum power requirements:
16.5 VAC 40 VA transformer
l
12 VDC 7Ah battery
l
RX+
RX-
TX+
TX-
GND
9
2
1
AUDIO/DEFAULT
3
RJ-45
COM
4

Advertisement

Table of Contents
loading

Table of Contents