KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual
3-2-3. Amplifier
3-2-4. Assembling the Fiber Unit to the Amplifier
Make the projection on the fiber unit facing toward a position where the LED does not exist on the
amplifier and insert it completely until it is in contact with the far side.
After the fiber has been inserted until it is in contact with the far side, turn the connector clockwise to
check that the fiber unit cannot be removed.
Figure 3-2-2 Mounting the Amplifier
Fiber unit
Projection
Figure 3-2-3 Assembling the Fiber Unit
Amplifier
3-3
MNLA motor cover
Bad mark sensor
amplifier
Washer assembled
hexagon socket head
×
cap bolt (
2)