Replacing The Ups Battery - JUKI KE-2050 Maintenance Manual

High speed modular mounter
Table of Contents

Advertisement

KE-2050/KE-2060, KE-2050R/2055R/KE-2060R Maintenance Manual

14-10-2. Replacing the UPS Battery

WARNING
14-10-2-1. Detaching the UPS
(1) Disconnect the connectors connected to the UPS and the relay connectors of the cable
coming from the UPS.
Disconnect the
connector from the
communication
connector.
Remove the screw
of the metallic
plate for securing
the UPS.
(2) Remove the metallic screws securing the terminal block metallic plate in front of the UPS and
those securing the UPS main unit, and then pull out the UPS toward the front.
To prevent fatal accidents due to electrical shock, always turn OFF
the main switch firmly.
Make sure that the main circuit breaker and the main switch of the
machine main unit are turned OFF. The main switch described
above is the power switch installed in the building and is not the
power switch of the machine main unit.
14-65
Disconnect the
plug from the
output socket.
Rev. 2.00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ke-2050rKe-2055rKe-2060Ke-2060r

Table of Contents