Epson Perfection4180 Photo Service Manual page 50

Color image scanner. auto document feeder
Table of Contents

Advertisement

EPSON Perfection4180 Photo
5.
Disconnect the Inverter Cable Connector and Fluorescent Lamp Connector from the
TPU Inverter Board.
When reinstalling the TPU Inverter Board, route the cables into the
five notches indicated by A, B and C.
A
A
6.
Remove the two screws (CBP, M3x6) that are securing the Inverter Board, and remove
the Inverter Board together with the Protective Sheet.
7.
Open the Protective Sheet and remove the Inverter Board.
DISASSEMBLY/ASSEMBLY
B
C
B
C
Disassembly Procedure
M3x6
Tightening torque 3.5±0.5kgfcm
Fluorescent Lamp Connector
Figure 4-32. Removal of Connector Cables
Protective Sheet
Figure 4-33. Removal of TPU Inverter Board
Revision A
Inverter Cable Connector
Inverter Board