11. Put back and secure the hairpin retaining wires.
12. Connect the bulb power wire to the red power wire.
13. Tighten the retaining screw on the flange.
14. Place the reflector in position in the body of the spotlight.
15. Replace the rubber "O" ring in the groove around the perimeter of the reflector.
16. Replace glass and retaining ring so the screw holes are aligned.
17. Secure retaining ring with two screws.
18. Replace rubber bezel.
19. Operate switch to ensure proper operation of spotlight.
W W A A R R N N I I N N G G
T T o o r r e e d d u u c c e e t t h h e e r r i i s s k k o o f f e e l l e e c c t t r r i i c c s s h h o o c c k k , , r r e e p p l l a a c c e e b b u u l l b b w w i i t t h h 6 6 v v o o l l t t H H 3 3 5 5 5 5 w w a a t t t t
o o n n l l y y . .
B B a a t t t t e e r r y y R R e e p p l l a a c c e e m m e e n n t t / / D D i i s s p p o o s s a a l l
B B a a t t t t e e r r y y R R e e p p l l a a c c e e m m e e n n t t
The battery should last the service life of the unit. Contact your Service Center for any
information you may need.
S S a a f f e e B B a a t t t t e e r r y y D D i i s s p p o o s s a a l l
Contains a maintenance-free, sealed, non-spillable, lead acid battery,
which must be disposed of properly. Recycling is required, contact your
local authority for information. Failure to comply with local, state and
federal regulations can result in fines, or imprisonment.
W W A A R R N N I I N N G G S S
• • D D o o n n o o t t d d i i s s p p o o s s e e o o f f t t h h e e b b a a t t t t e e r r y y i i n n f f i i r r e e a a s s t t h h i i s s m m a a y y r r e e s s u u l l t t i i n n a a n n
e e x x p p l l o o s s i i o o n n . .
• • B B e e f f o o r r e e d d i i s s p p o o s s i i n n g g o o f f t t h h e e b b a a t t t t e e r r y y , , p p r r o o t t e e c c t t e e x x p p o o s s e e d d t t e e r r m m i i n n a a l l s s w w i i t t h h h h e e a a v v y y - -
d d u u t t y y e e l l e e c c t t r r i i c c a a l l t t a a p p e e t t o o p p r r e e v v e e n n t t s s h h o o r r t t i i n n g g ( ( s s h h o o r r t t i i n n g g c c a a n n r r e e s s u u l l t t i i n n i i n n j j u u r r y y
o o r r f f i i r r e e ) ) . .
• • D D o o n n o o t t e e x x p p o o s s e e b b a a t t t t e e r r y y t t o o f f i i r r e e o o r r i i n n t t e e n n s s e e h h e e a a t t a a s s i i t t m m a a y y e e x x p p l l o o d d e e . .
1 1 2 2 V V o o l l t t D D C C C C h h a a r r g g i i n n g g A A d d a a p p t t e e r r P P l l u u g g F F u u s s e e R R e e p p l l a a c c e e m m e e n n t t
The fuse in the plug end of the 12 Volt DC Charging Adapter protects the adapter's
charging circuit. If the Wall Cube Charger (AC) operates, but the DC charging
adapter does not, then this fuse may be opened (blown).
To replace the fuse:
1. Unscrew the end cap of the DC plug (counterclockwise).
2. Remove spring center contact and fuse.
3. Check fuse with a continuity checker.
4. If blown, locate a replacement 0.5 amp/250 volt fuse.
20
5. Replace the fuse, spring, contact and end cap
6. Screw end cap clockwise until it is finger tight – DO NOT OVER-TIGHTEN.
7. Test for proper operation of the 12 Volt DC Charging Adapter.

TROUBLESHOOTING

N N o o B B a a t t t t e e r r y y S S t t a a t t u u s s I I n n d d i i c c a a t t o o r r L L E E D D s s L L i i g g h h t t W W h h e e n n C C h h a a r r g g i i n n g g
1. Check connection to the Wall Cube Charger (AC) or 12 Volt DC Charging Port.
2. Check connection to AC or DC power source.
3. Confirm there is a functioning AC or DC current.
U U n n i i t t W W i i l l l l N N o o t t O O p p e e r r a a t t e e
1. The Spotlight will not operate when charging. Be sure all adapters are
disconnected before Spotlight use.
2. If you suspect the bulb is blown, check the filament. If the filament is coiled and
unbroken, the bulb is not blown. If bulb is blown, replace it.
3. The battery may be completely discharged. Charge the unit following the
directions on this manual.
4. If the Spotlight does not operate after recharging as directed, contact your
Service Cente.
S S p p e e c c i i f f i i c c a a t t i i o o n n s s
VEC156BD
AR
Voltage
220V
Frequency
50Hz
DC Plug Fuse
0.5 A/250V
AC Charger
15V (200mA)
B3
B2C
BR
120V
220V
127V/220V
60Hz
50Hz
60Hz
0.5 A/250V
0.5 A/250V
0.5 A/250V
12V (300mA) 12V (300mA) 15V (300mA)
21

Advertisement

loading

This manual is also suitable for:

1 million power vec156bd