Remote Switch Installation; Alternate Switch Location; Eb-1 Electrical Box - Majestic fireplaces NV360 Series Homeowner's Installation And Operating Manual

Decorative gas appliance
Table of Contents

Advertisement

1/2" Gas Supply
FP297a
Fig. 4 Typical gas supply installation.
The fireplace valve must not be subjected
to any test pressures exceeding 1/2 psi.
Isolate or disconnect this or any other gas
appliance control from the gas line when
pressure testing.
The gas control is equipped with a captured screw type
pressure test point, therefore it is not necessary to pro-
vide a 1/8" test point up stream of the control.
When using copper or flex connector use only approved
fittings. Always provide a union when using black iron
pipe so that the gas line can be easily disconnected for
burner or fan servicing. (Fig. 4) See the gas specifica-
tions for pressure details and ratings.
Remote ON/OFF Switch Installation
Do not wire the remote ON/OFF wall switch
for this gas appliance into a 120v power
supply.
1. Thread wire through the electrical knockout located
on either side of the unit. Take care not to cut the
wire or insulation on metal edges. Ensure the wire is
secured and protected from possible damage. Run
one end of the gas control valve and the other end to
the conveniently located wall switch.
2. Attach the wire to the ON/OFF switch and install
switch into receptacle box. Attach cover plate to
switch.
3. Connect wiring to gas valve. (Fig. 5)
Thermopile
Fig. 5 Remote switch wiring diagram for R models.
20003565
1/2" NPT x 3/8" Flare
Shut-off Valve
3/8" Flex Line
(from valve)
FP297A
INSTA VENT FREE
UVHB26 GAS SUPPLY
7/1/98
W584-9
W584-9
WIRING DIAGRAM
1/8/99 djt
11/9/99 added thermopile

Alternate Switch Location

The remote switch can be installed on either side of
the access door. Mount the switch to the switch bracket
provided. Screw the bracket on either side of the frame,
line up the screws with the prepunched holes. (Fig. 6)
Fig. 6 Alternate switch location.

EB-1 Electrical Box

The fireplace, when installed, must be elec-
trically connected and grounded in accor-
dance with local codes or, in the absence
FP1024
of local codes, with the current CSA C22.1
Canadian Electrical Code.
alternate
For USA installations, follow local codes
remote switch
and the National Electrical Code, ANSI/
NFPA No. 70.
location
It is strongly suggested that the wiring of
the EB-1 electrical junction box be carried
1/27/00 djt
out by a licensed electrician.
Ensure that the power to the supply line
has been disconnected before commenc-
ing this procedure.
The EB-1 electrical junction box has been
supplied standard on the NV360/580 models to allow
for the easy installation of an optional fan kit.
To connect the EB-1 box to the house electrical supply,
follow the steps below:
1. Unscrew the retaining screw from the EB-1 base
plate (fig. 7) and remove the EB-1 assembly from
the fireplace.
2. Remove the front cover of the EB-1 box.
3. Remove the plug socket assembly form the EB-1
box.
4. Feed the supply line in from the outside through the
cable clamp. (Fig. 7)
5. Connect black wire of the power supply line to the
brass screw (polarized) of the socket assembly.
NV360/580 Series
FP1024
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nv580 seriesNv360rnNv360rpNv580rnNv580rp

Table of Contents