NV360/580 Series
Honeywell VS8420 Standing Pilot
16
Troubleshooting
START
Gas Supply ON
YES
Pilot Lights with
Piezo Ignitor
YES
Pilot Stays Lit
YES
Pilot Lights
Main Burner
YES
System OK
FP396b
HV standing pilot
troubleshoot
Remove Glass Panel Before Servicing.
CHECK
• Supply line hooked up
NO
• Shutoff valve open
• Lockout has engaged. Wait
60 seconds and try again.
• For spark at electrode while
NO
depressing Piezo - 1/8" gap to
pilot hood needed.
• All wiring connections
• Replace Piezo ignitor
• For air in lines
• Thermopile needs a minimum
325mV. Adjust pilot flame height.
• All Wiring connections
• Replace thermopile
NO
• Thermocouple needs a minimum
14mV.
• Defective valve. Turn to pilot,
meter should read greater than
100mV. If not, replace.
• Valve is turned on
• Wall switch is not turned on.
NO
Watch for grounded wires!
• Thermopile needs a minimum
325mV.
• Plugged burner orifice.
FP396a
20003565