NV360/580 Series
Fan Kits
FK12 Fan Assembly
1. Open louvre assembly bottom.
2. Install FK12 fan in back of unit between hearth sup-
ports. (Fig. 32)
3. Secure fan on velcro strips.
4. Power to the fan can be supplied by plugging the
supply lead into a conveniently located wall socket
or by using a hard-wired EB-1 connector box.
5. Be sure fan motor does not touch hearth supports.
Side View
Front of
Unit
Hearth Pan
Base Pan
Fig. 32 FK12 Fan Kit placement.
FK24 Fan Assembly
FP1004
Fan specifications: 120 volt, 60 Hz, .75 Amp.
Fan placement
This fan does not need regular maintenance, however
DV360/580 Series
periodic cleaning is required. Check the area under the
1/25/00 djt
control door and in front of the fan and wipe or vacuum
at least once a month during the operating season.
Should this fan require servicing, the power supply must
be disconnected.
The FK24 comes with the electrical cord attached.
1. Slide fan assembly from the left side into the fire-
place opening, line up mounting holes with screw
studs on back of fireplace and fasten with #10 - 24
hex nuts. (Fig. 76)
2. Install thermal sensor on bottom of firebox using #10
- 24 hex nuts.
3. (Option A) - Place electronic fan speed control box
on bottom of fireplace base, lining up mounting holes
with screw studs. Fasten fan speed control box with
#10 - 24 hex nuts.
(Option B) - The speed control can be installed in an
electrical box at normal wall switch height for conve-
nient access.
4. The power supply may be connected in 2 ways:
24

Accessories

Method A
Route the 6' (1.8m) lead fitted to the unit to a conve-
niently located wall socket.
Method B
If the EB-1 receptacle box (Pt. #ZA1200) was cor-
rectly connected when the unit was installed, the
fan lead can be directly plugged into the EB-1 plug
socket.
5. Whether wiring directly to the fan junction box (Op-
tion A) or into the EB1 (electrical box, Option B) first
ensure cable is secured using box connector.
Cold Air
Box
FK12 Fan
First connect ground wire to ground stud located on
the base of either box. Black wire from supply should
connect to the variable speed switch. Alternate speed
FP1004
switch wire connects to temperature sensor. Alternate
lead from sensor connects to fan. Alternate fan lead
connects back to the white supply wire. (Fig. 34)
Electrical Box
FP1026
Fig. 33 FK24 fan placement.
Speed
Control
Black
White
Ground
Fig. 34 FK24 fan wiring.
The fireplace, when installed must be elec-
trically connected and grounded in accor-
dance with local codes, with the current
CSA C22.1 Canadian Electrical Code or for
US installations, follow local codes and
the National Electrical Code, ANSI/NFPA
No. 70.
Hard (Direct) Wire Hook Up
Any electrical rewiring of this fan must be
completed by a qualified electrician.
Turn off all power before hook up.
Heat Sensor
Fan Speed
Switch
Temperature
Sensor
FP394
WIRING DIAGRAM
11/20/96
Fan
Valve
Gas Line
FP1026
Fan
FK24
fan placement
1/27/00 djt
FP1025
20003565