INSTALLER/CONSUMER

SAFETY INFORMATION

DO NOT INSTALL THE APPLIANCE IN
THIS FIREBOX, UNLESS THIS
FIREBOX MEETS THE MINIMUM
DIMENSIONS REQUIRED FOR THE
INSTALLATION.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
FOR USE ONLY WITH A LISTED
GAS-FIRED, UNVENTED,
DECORATIVE ROOM HEATER NOT TO
EXCEED 40,000 BTU/H
DO NOT BUILD A WOOD FIRE.
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC AND AWAY FROM
FURNITURE AND DRAPERIES.
Do not attempt to modify or alter the
construction of the appliance or its
components. Any modification or
alteration of construction may void the
warranty of these units.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
Improper maintenance or service can
cause injury or property damage. Refer
to this manual. For additional infor-
mation, consult a qualified installer,
service agency, or the gas supplier.
Carefully review the instructions supplied
with the decorative type unvented room
heater for the minimum fireplace size
requirement.
Vent-Free Fireboxes
Models: UVSTR36, UVCVR36
Homeowner's Installation and
These Ventless Fireboxes are design
certified to ANSI 21.91.2001 and are for
use with any ANSI Z21.11.2 Unvented
Room Heaters.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
UVCVR36
Operating Manual
UVSTR36
FP678 UVSTR/UVCVR
4/20/98
7412960 10/06 Rev. 4

Advertisement

Table of Contents
loading

Summary of Contents for Majestic fireplaces UVCVR36

  • Page 1: Safety Information

    Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fireplace size requirement. Vent-Free Fireboxes Models: UVSTR36, UVCVR36 UVCVR36 Homeowner's Installation and Operating Manual These Ventless Fireboxes are design certified to ANSI 21.91.2001 and are for use with any ANSI Z21.11.2 Unvented...
  • Page 2: Table Of Contents

    UVSTR / UVCVR Series Vent-Free Fireboxes The UVSTR36 and UVCVR36 models are ventless fireboxes designed for installation with any ventless gas log set for a see-through application and certified to ANSI Z21.11.2 standards. THESE UNITS ARE DESIGNED FOR A MAXIMUM OF 40,000 BTU. Optional hoods are available. Refer to page 13.
  • Page 3: General Information

    • Installation of any damaged firebox. • Modification of the firebox or any of the compo- nent parts thereof. • Installation other than as instructed by CFM Cor- poration. • Installation and/or use of any component part or accessory not manufactured or approved by CFM Corporation in combination or assembly with a Majestic Fireplaces firebox, notwithstand-...
  • Page 4: Specifications And Framing

    Opening Depth 36" 12" Outside Air Fig. 1 UVSTR36 Series specification and framing dimensions. Rough Opening Height 36" Fig. 2 UVCVR36 Series specification and framing dimensions. UVSTR36 Specifications �����" Rough Opening Width 41" Rough Opening Height 40���" 36" 14���" 40"...
  • Page 5: Clearances

    UVSTR / UVCVR Series Vent-Free Fireboxes (Top View) FINISHED WALL MANTEL TRIM 42" Min. 2" DRYWALL (Side View) 8" MANTEL SHELF 1¹⁄₂" 12" 8" UVSTR/UVCVR36 Fig. 4 Hearth dimensions. COMBUSTIBLE MANTEL TRIM FIREBOX 2" 4¹⁄₂" 4¹⁄₂" NONCOMBUSTIBLE FACING MATERIAL Front leg of grate 3"...
  • Page 6: Installation

    If the outside air kit is to be used, the AKU2 MUST be installed BEFORE the fireplace is enclosed. Refer to the AKU2 instructions for field installation. UVSTR36 UVCVR36 Fig. 5 Adjustable drywall strip (nailing flange). Nail Top Standoffs Nail Eight...
  • Page 7 Connect the Gas Line Gas access holes are provided on both sides of the firebox. Check gas valve type. Use only the gas type indicated on the gas log rating plate. If the gas listed on the plate is not your type of gas supply, DO NOT INSTALL. Con- tact your Dealer for the proper model.
  • Page 8 UVSTR / UVCVR Series Vent-Free Fireboxes Fig. 7 Insulation between firebox and platform. Fig. 8 Additional insulating methods. UVSTR36 shown. FP682 4/21/98 See Page 5, Figure 3 for allowable finishing materials and clearances to combustibles. Hard Flat Surface All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround must be completely sealed with a noncombustible ma- terial.
  • Page 9 1/26/98 A 2" or 4" Hood can be purchased for the UVSTR36 and the UVCVR36. A Hood must be installed if the mantel falls within the dimensions and location shown in Figure 3. Failure to do so may create a fire hazard.
  • Page 10: Maintenance

    Leave at least a 36" clearance from the front of the firebox to any room furnishings. Contact CFM Corporation for questions concerning prices and policies covering replacement parts. Parts may be ordered through your Majestic Fireplaces dis- tributor or dealer.
  • Page 11 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UVCVR Vent Free Firebox Ref. Description Brick - Filler Brick - Side Brick - Hearth Screen Assembly (Screens and Rod)
  • Page 12 UVSTR / UVCVR Series Vent-Free Fireboxes CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UVSTR Vent Free Firebox Ref. Description Brick - Filler Brick - Side...
  • Page 13: Accessories

    CAUTION: This firebox is a highly engineered system, and, as such, must be operated only with CFM Corporation approved components. If you use an unapproved component to make any modifications, you may create a possible fire hazard and will void CFM Corporation warranty. In addition, such action may void the coverage provided by the owner’s insurance.
  • Page 14 UVSTR / UVCVR Series Vent-Free Fireboxes 7412960...
  • Page 15: Warranty

    Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions and limitations.
  • Page 16 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com...

This manual is also suitable for:

Uvstr36

Table of Contents