INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
IMPORTANT: Read all instruc-
tions and warnings carefully
before starting installation. Fail-
ure to follow these instructions
may result in a possible fire
hazard and will void the warranty.
WARNING: If the information in
this manual is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified installer,
service agency, or the gas sup-
plier. Do not store or use gaso-
line or other flammable vapors
and liquids in the vicinity of this
or any other appliance.
FOR YOUR SAFETY
If you smell gas:
Do not touch electrical switches.
Do not try to light any appliance.
Extinguish any open flame.
Do not use the phone in your
building.
Immediately call your gas sup-
plier from a neighbor's phone.
Follow your gas supplier's in-
structions.
If you cannot reach your gas
supplier, call the fire department.
INSTALLER: DO NOT DISCARD THIS MANUAL LEAVE FOR HOMEOWNER.
Decorative Gas Appliance
Models: NVC36
Installation and Homeowners
Operating Instructions
Vermont Castings, Majestic Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
NVC39
NVC43
"
C E RT I F I E D
20000194 12/02 Rev. 3

Advertisement

Table of Contents
loading

Summary of Contents for Majestic fireplaces NVC36

  • Page 1 BEFORE INSTALLING AND USING APPLIANCE Decorative Gas Appliance IMPORTANT: Read all instruc- tions and warnings carefully Models: NVC36 before starting installation. Fail- ure to follow these instructions NVC39 may result in a possible fire hazard and will void the warranty.
  • Page 2: Table Of Contents

    Majestic Fireplaces NVC Series B-Vent ® Table of Contents Thank you and Congratulations on your purchase of a Vermont Castings Majestic Products Company fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Installation Instructions

    Majestic Fireplaces NVC Series B-Vent ® Installation & Operating Instructions This gas appliance should be installed by a qualified 11. Whether the appliance is installed directly on installer in accordance with local building codes and carpeting, vinyl tile or any combustible material other with current CSA-B149.1 Installation codes for Gas...
  • Page 4: Fireplace Dimensions

    Majestic Fireplaces NVC Series B-Vent ® Fireplace Dimensions INSET A 10" 5⁷⁄₈" 6" 7³⁄₈" Flue 3⁵⁄₈" 10" = 254mm Finished Wall Rough Opening Width 7³⁄₈" = 187mm Thickness 5⁷⁄₈" = 149mm 3⁵⁄₈" = 92mm Rough Opening Gas Line Height Access 2"...
  • Page 5: Clearance To Combustibles

    Majestic Fireplaces NVC Series B-Vent ® Clearance to Combustibles Appliances Top ........... 0” (0mm) Bottom ........0” (0mm) Side ......... 0” (0mm) Back ......... 0” (0mm) Perpendicular Sidewall .... 0” (0mm) Black Surround Top of unit to ceiling ....36” (914mm) Face Front of unit to combustibles ...
  • Page 6: Framing And Finishing

    14.0" w.c. 14." w.c. 5/8” / 16mm 3/4” / 19mm Manifold Pressure 3.5" w.c. 10.0" w.c. NVC36 / NVC39 / NVC43 CERTIFIED TO ANSI Z21.50a-1999 / CGA 2.22a-M99 Vented Gas Fireplace Heaters Adjustable 1/2”, 5/8” & 3/4” Spacing High Elevations...
  • Page 7: Gas Line Installation

    Majestic Fireplaces NVC Series B-Vent ® Gas Line Installation 1/2" Gas Supply 1/2" x 3/8" Shut-off Valve When purging gas line the fornt glass must be reomvoed. Purging gas lines 3/8" Nipple must comply with the NFPA-54 or B-149. 3/8" Union The gas pipeline can be brought in through the right or 3/8"...
  • Page 8: Eb-1 Electrical Box

    Majestic Fireplaces NVC Series B-Vent ® EB-1 Electrical Box Inside Electrical Box The fireplace, when installed, must be Retaining Screw electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code...
  • Page 9: Venting Runs

    Majestic Fireplaces NVC Series B-Vent ® Venting Runs Attic Installation Firestop position when area above ceiling is an attic. Horizontal Run (in feet) Nails (4) 5 6 7 8 9 10 11 12 Firestop Spacer Joist Ceiling Installation Firestop position when area above ceiling is NOT an attic.
  • Page 10: Operating Instructions

    • Replacement glass (complete with gasket) is Window Frame available through your Majestic Fireplaces dealer Assembly and should only be installed by a licensed qualified Window Frame service person.
  • Page 11: Lava Rock, Ember Material Placement

    Majestic Fireplaces NVC Series B-Vent ® 5. Place the front right log on top of the burner, Use Lava Rock bottom holes to locate the logs on top of the studs. The lava rock provided with this fireplace must be Ensure 6.
  • Page 12: Inspecting The Venting System

    Majestic Fireplaces NVC Series B-Vent ® Test Chimney Draw NVC36 A "Chimney Draw" test must be made before the installation is complete. 1. Close all doors and windows in the home and start exhaust fans in the kitchen and bathroom.
  • Page 13: Lighting And Operating Instructions

    Majestic Fireplaces NVC Series B-Vent ® Lighting And Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit •...
  • Page 14: Vent Safety Switch

    Majestic Fireplaces NVC Series B-Vent ® Vent Safety Switch Electrical Connection This fireplace incorporates the use of a Vent Safety The sensor is wired in series between the wall mounted Shut-off Switch. The sensor and wiring are factory ON/OFF switch and the Electronic Ignition Module (Fig.
  • Page 15: Troubleshooting

    Majestic Fireplaces NVC Series B-Vent ® Troubleshooting Honeywell Electronic Ignition START CHECK : Line Voltage (120VAC) Turn gas supply off Low Voltage Transformer Turn ON/OFF Switch (19.5 minimum VAC) to call for heat. ON/OFF Switch Wiring connections Power to module...
  • Page 16 Majestic Fireplaces NVC Series B-Vent ® Troubleshooting Honeywell VS8421 Remove glass door before service work CHECK START Gas Supply On • Supply Line Hooked Up • Shutoff Valve Open • Lockout Has Engaged. Wait 60 Seconds And Try Again. •...
  • Page 17 Majestic Fireplaces NVC Series B-Vent ® Troubleshooting Nova SIT 820 Standing Pilot START CHECK Supply Line Hooked Up Gas Supply On Shutoff Valve Open Lockout Has Engaged. Wait 60 Seconds and Try Again. Piezo Nut Tight for Good Ground. Pilot Lights With...
  • Page 18: Maintenance

    Majestic Fireplaces NVC Series B-Vent ® Maintenance Burner and Burner Compartment To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not lifting It is important to keep the burner and the burner or floating.
  • Page 19: Part Pictorial

    Majestic Fireplaces NVC Series B-Vent ® NVC43 Logs 1 NVC39 NVC36 SIT Valve 15-16a/b 6a/b NOVA SIT 822 VALVE 20/21 17a/b 7a/b 4a/b MVPV (BURNER) SENSE SPARK 8a/b 39a/b 40 a/b Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
  • Page 20: Parts List

    Majestic Fireplaces NVC Series B-Vent ® NVC36/39/43 (continued) Ref. Description NVC36 NVC39 NVC43 Burner Housing w/tile-LP 10000028 10000694 10000030 Ceramic tile (Single) 57803 57803 57803 Orifice Front Burner-Nat. See Rating Plate Orifice Front Burner-LP See Rating Plate Pilot Assy-LP (SIT Pilot 4 Way)
  • Page 21: Optional Accessories

    Majestic Fireplaces NVC Series B-Vent ® Optional Accessories The fireplace, when installed must be electrically Fan Kits connected and grounded in accordance with local FK12 Fan Assembly codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or for 1.
  • Page 22: Wiring Instructions

    Majestic Fireplaces NVC Series B-Vent ® Remote Controls Adjustable Adjustable Optional remote control units are available to control different functions of the appliance. Model Function(s) Controlled MRC1 ON/OFF Side Side MRC2 ON/OFF and Temperature Panel Panel MRC3 ON/OFF and Temperature control...
  • Page 23: Ceramic Refractory Panels

    Majestic Fireplaces NVC Series B-Vent ® Louvre Assembly Top Window Frame Ceramic Ceramic Refractory Refractory Spacers Louvre Assembly FP1196 Bottom Bottom Brass Fig. 28 Arched door front in place. Trim Screws FP1195 Decorative Bay Windows Fig. 29 Bay window. When fitting the Bay Window Kits, the original front frame/glass assembly MUST remain in place.
  • Page 24: Receptacle Box

    Majestic Fireplaces NVC Series B-Vent ® LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.

This manual is also suitable for:

Nvc39Nvc43

Table of Contents