Majestic fireplaces NVC36 Operating Instructions Manual

Decorative gas fireplace

Advertisement

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE
IMPORTANT: Read all instructions
and warnings carefully before starting
installation. Failure to follow these
instructions may result in a possible
fire hazard and will void the warranty.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
FOR YOUR SAFETY
Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier. Do
not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
FOR YOUR SAFETY
If you smell gas:
Do not touch electrical switches.
Do not try to light any appliance.
Do not use the phone in your building.
Immediately call your gas supplier from
a neighbor's phone.
Follow your gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
Decorative Gas Fireplace
Models: NVC36, NVC39, NVC43
Installation and Homeowners
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Operating Instructions
GF461
NVC cover
3/3/97
C E RT I F I E D
20000194 11/07 Rev. 7

Advertisement

Table of Contents
loading

Summary of Contents for Majestic fireplaces NVC36

  • Page 1 Decorative Gas Fireplace Models: NVC36, NVC39, NVC43 INSTALLER/CONSUMER SAFETY INFORMATION PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 2: Table Of Contents

    NVC Series B-Vent Table of Contents Thank you and Congratulations on your purchase of a CFM Corporation fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: General Information, Warnings, Cautions

    (3.45 kPa). draperies. NVC36 / NVC39 / NVC43 2. Children and adults should be alerted to the hazards of the CERTIFIED To high surface temperatures of this appliance and should stay away to avoid burns or ignition of clothing.
  • Page 4: Installation Instructions

    NVC Series B-Vent Installation & Operating Instructions Requirements for the Commonwealth of Inspection Massachusetts The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not All gas fitting and installation of this heater shall only be approve the installation unless, upon inspection, the done by a licensed gas fitter or licensed plumber.
  • Page 5: Fireplace Dimensions

    (See inset A) Do not install header until Rough unit is in place. Opening Depth Fig. 1 Fireplace specifications and framing dimensions. Appliance Dimensions Ref. NVC36 NVC39 NVC43 Framing Dimensions ������� 36¹⁄₂" (927 mm) 39¹⁄₂" (1003 mm) 43¹⁄₂" (1105 mm) ��������...
  • Page 6: Clearance To Combustibles

    NVC Series B-Vent Clearance to Combustibles Appliances Top ............0” (0 mm) Bottom ............. 0” (0 mm) Side ............0” (0 mm) Back ............0” (0 mm) Perpendicular Sidewall ......0” (0 mm) Black Top of unit to ceiling ......36” (914 mm) Surround Front of unit to combustibles .....
  • Page 7: Framing And Finishing

    NVC Series B-Vent Framing and Finishing Gas Specifications Max. Min. Check fireplace to make sure it is levelled Model Fuel Gas Control Input Input and properly positioned. NVC36RN Natural Millivolt Hi/Lo 25,000 17,500 NVC36RP Propane Millivolt Hi/Lo 25,000 18,750 1. Choose the unit location. NVC36VN Natural 24V Hi/Lo*...
  • Page 8: Gas Line Installation

    NVC Series B-Vent Gas Line Installation 1/2" Gas Supply When purging gas line the fornt glass must 1/2" x 3/8" Shut-off Valve be removed. Purging gas lines must com- 3/8" Nipple ply with ANSI Z223.1/NFPA 54 in USA and 3/8" Union CSA B149.1 in Canada.
  • Page 9: Eb-1 Electrical Box

    NVC Series B-Vent EB-1 Electrical Box Inside Electrical Box The fireplace, when installed, must be Retaining Screw electrically connected and grounded in accordance with local codes or, in the ab- sence of local codes, with the current CSA C22.1 Canadian Electrical Code For USA installations follow the local codes and the national electrical code ANSI/NFPA No.
  • Page 10: Venting Runs

    NVC Series B-Vent Venting Runs Attic Installation Firestop position when area above ceiling is an attic. Horizontal Run (in feet) Nails (4) 5 6 7 8 9 10 11 12 Firestop Spacer Joist Ceiling Installation Firestop position when area above ceiling is NOT an attic. (Firestop/draftstop appearances may vary.
  • Page 11: Operating Instructions

    NVC Series B-Vent Operating Instructions Glass Information Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass. Lower •...
  • Page 12: Lava Rock, Ember Material Placement

    BC8 Log Top Left to decrease to increase Log Top Right flame height flame height Rear HV102 BC5 Log NVC36 LOG SET Fig. 13 Flame adjustment knob for Honeywell valve. Front 8-11-98 Log Front Left Right Turn counterclockwise Turn clockwise...
  • Page 13: Inspecting The Venting System

    NVC Series B-Vent Test Chimney Draw NVC36 A "Chimney Draw" test must be made before the instal- lation is complete. 1. Close all doors and windows in the home and start exhaust fans in the kitchen and bathroom. 2. Light unit and operate for 5 minutes.
  • Page 14: Lighting And Operating Instructions

    NVC Series B-Vent Lighting and Operating Instructions FOR YOUR SAFETY READ BEFORE LIGHTING WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This heater has a pilot which must be lit manu- •...
  • Page 15: Vent Safety Switch

    NVC Series B-Vent Vent Safety Switch Electrical Connection This fireplace incorporates the use of a Vent Safety The sensor is wired in series between the wall mounted Shut-off Switch. The sensor and wiring are factory ON/OFF switch and the Electronic Ignition Module (Fig. installed and should not be removed or altered during 19) or the thermopile and the gas valve (Fig.
  • Page 16: Troubleshooting

    NVC Series B-Vent Troubleshooting Honeywell Electronic Ignition START CHECK : Line Voltage (120VAC) Turn gas supply off Low Voltage Transformer Turn ON/OFF Switch (19.5 minimum VAC) to call for heat. ON/OFF Switch Wiring connections Power to module Thermodisk (24V nominal) Unplug Ignition Lead and check spark Replace Module...
  • Page 17 NVC Series B-Vent Troubleshooting Honeywell VS8421 Remove glass door before service work CHECK START • Gas Supply On Supply Line Hooked Up • Shutoff Valve Open • Lockout Has Engaged. Wait 60 Seconds And Try Again. • For Spark At Electrode While Depressing Piezo Pilot Lights With Piezo 1/8"...
  • Page 18 NVC Series B-Vent Troubleshooting Nova SIT 820 Standing Pilot START CHECK Supply Line Hooked Up Gas Supply On Shutoff Valve Open Lockout Has Engaged. Wait 60 Seconds and Try Again. Piezo Nut Tight for Good Ground. Pilot Lights With For Spark at Electrode While Piezo Ignitor Depressing Piezo (Red Button) - 1/8"...
  • Page 19: Maintenance

    NVC Series B-Vent Maintenance Burner and Burner Compartment To obtain proper operation, it is imperative that the pilot It is important to keep the burner and the burner and burner’s flame characteristics are steady, not lifting compartment clean. At least once per year the logs and or floating.
  • Page 20: Replacement Parts

    NVC Series B-Vent NVC43 Logs 1 NVC39 NVC36 SIT Valve 15-16a/b 6a/b NOVA SIT 822 VALVE 20/21 17a/b 7a/b 4a/b MVPV SPARK (BURNER) SENSE 8a/b 39a/b 40 a/b CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice.
  • Page 21: Parts List

    NVC Series B-Vent NVC36/39/43 (continued) Ref. Description NVC36 NVC39 NVC43 Burner Housing w/tile-Nat 10000027 10000033 10000029 Burner Housing w/tile-LP 10000028 10000694 10000030 Ceramic tile (Single) 57803 57803 57803 Orifice Front Burner-Nat. See Rating Plate Orifice Front Burner-LP See Rating Plate...
  • Page 22 NVC Series B-Vent NVC36/39/43 (continued) Ref. Description NVC36 NVC39 NVC43 40a. Valve - Honeywell VS8421 - Nat. 10001782 10001782 10001782 40b. Valve - Honeywell VS8421 - LP 10001759 10001759 10001759 Vent Safety Switch 10002013 10002013 10002013 20000194...
  • Page 23: Optional Accessories

    NVC Series B-Vent Optional Accessories The fireplace, when installed must be electrically Fan Kits connected and grounded in accordance with local FK12 Fan Assembly codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code or for 1.
  • Page 24: Remote Controls

    Ceramic refractory panels are available to line the fire- Panel Refractory box area. Panel Unit Kit Model Lower Side Supports FP1193 NVC36 NV36CR NVC39 NV39CR Fig. 24 Install ceramic refractory panels. NVC43 NV43CR Take care when handling the refractory panels as they Rear Refrac- tory Panel are fragile until held in place and supported.
  • Page 25: Decorative Bay Windows

    NVC Series B-Vent Louvre As- sembly Top Window Frame Ceramic Ceramic Refractory Refractory Spacers Louvre FP1196 Assembly Bottom Bottom Fig. 28 Arched door front in place. Brass Trim Screws FP1195 Decorative Bay Windows FP1195 Fig. 29 Bay window. Arched door front When fitting the Bay Window Kits, the original 2/27/02 djt front frame/glass assembly MUST remain in place.
  • Page 26 NVC Series B-Vent 20000194...
  • Page 27: Warranty

    NVC Series B-Vent LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY •...
  • Page 28: Energuide

    Efficiency Ratings Model EnerGuide Ratings Fireplace Efficiency (%) NVC36RN 29.4 NVC36RP 29.4 NVC36RFN 29.4 NVC36RFP 29.4 NVC36EN 28.5 NVC36EP 28.5 NVC39RN 26.4 NVC39RP 26.4 NVC39RFN 26.4 NVC39RFP 26.4 NVC39EN 25.6 NVC39EP 25.6 NVC43RN 27.9 NVC43RP 27.9 NVC43RFN 27.9 NVC43RFP 27.9 NVC43EN 27.1 NVC43EP...

This manual is also suitable for:

Nvc39Nvc43

Table of Contents