INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READTHIS MANUAL
BEFORE INSTALLING AND USING
APPLIANCE.
WARNING: IF THE INFORMATION IN
THIS MANUAL IS NOT FOLLOWED EX-
ACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS
OF LIFE.
FOR YOUR SAFETY
Installation and service must be per-
formed by a qualified installer, service
agency, or the gas supplier.
What to do if you smell gas
Do not try to light any appliance
Do not touch any electric switch; do
not use any phone in your building.
Immediately call your gas upplier
for myour neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas sup-
plier, call the fire department.
DO NOT STORE OR USE GASO-
LINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER
APPLIANCE.
Decorative Gas Appliance
Model: NV360
NV580
:
Homeowner's Installation and
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Operating Manual
2261
DV360/580
cover
1/24/00 djt
C E RT I F I E D
20003565 7/06 Rev. 7

Advertisement

Table of Contents
loading

Summary of Contents for Majestic fireplaces NV360 Series

  • Page 1 LINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. Decorative Gas Appliance Model: NV360 NV580 Homeowner's Installation and Operating Manual INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.
  • Page 2: Table Of Contents

    NV360/580 Series Thank you and Congratulations on your purchase of a Majestic Fireplaces fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING THE APPLIANCE IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Installation & Operating Instructions

    11. Whether the appliance is installed directly on carpet- ing, vinyl tile or any combustible material other than 20003565 NV360/580 Series wood, this appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.
  • Page 4: Fireplace Dimensions

    NV360/580 Series � � � � � Outside Air Electrical Access Fig. 1 Fireplace specifications and framing dimensions. Ref. Fireplace Dimensions Rough Opening Depth � � � T - Rough Opening Width Rough Opening Height NV360 41" (1046 mm) 37¹⁄₂"...
  • Page 5: Clearance To Combustibles

    Mantel From Top of Comb. Chamber 19" (483 mm) 17" (432 mm) 15" (381 mm) 13" (330 mm) 11" (279 mm) NV360/580 Series Black Surround Face Mantel Side of Combustion Chamber Mantel Ref. Mantel Leg From Leg Depth of Comb. Opening CFM170 14"...
  • Page 6: Framing & Finishing

    Gas Inlet & Manifold Pressures Natural 5.5" w.c. 14.0" w.c. 14.0" w.c. 3.5" w.c. NV360 / NV580 Certified to ANSI Z21.50b-2002 / CSA 2.22b-2002 Vented Gas Fireplace High Elevations Gas Line Installation When purging gas line the front glass must be removed.
  • Page 7: Remote Switch Installation

    (Fig. 6) Fig. 6 Alternate switch location. supplied standard on the NV360/580 models to allow for the easy installation of an optional fan kit. To connect the EB-1 box to the house electrical supply, follow the steps below: 1.
  • Page 8: Install The Venting System, Flashing And Termination

    FK12 or FK24 fan kits if fitted. Install the Venting System, Flashing and Termination NOTE: The NV360 uses a 6" B-vent system. The NV580 uses an 8" B-vent system (refer to Accessories, Page 23 for adapter).
  • Page 9: Venting Runs

    Up to a 12 ft. horizontal vent run can be installed within the vent system using a maximum of two (2) 45-degree elbows. Table 1 Venting configurations. FP567a 8' VENTING RUNS 12/00 20003565 8 9 10 11 12 FP567a NV360/580 Series...
  • Page 10: Operating Instructions

    NV360/580 Series Glass Information Only glass approved by CFM Corporation should be used on this fireplace. • The use of any non-approved replacement glass will void all product warranties. • Care must be taken to avoid breakage of the glass.
  • Page 11: Ember Material Placement

    Figures 15, 16 and 17. If any of the flames appear abnormal call a service person. 20003565 Log Top Left Log Front Left Fig. 11 NV360 log, lava rock and ember material placement. LG119 Log Top Center Left DV360 log placement Log Top...
  • Page 12: Inspecting The Venting System

    NV360/580 Series Turn counterclockwise to increase flame height Fig. 13 Flame adjustment knob for Honeywell valve. Turn counterclockwise to increase flame height HV102 Honeywell hi/lo knob 4/5/99 djt Fig. 14 Flame adjustment knob for SIT 820 valve. 3/8" - 1/2"...
  • Page 13: First Firing

    Electrical Connection FP1160 The sensor is wired in series between the wall mounted Vent safety switch "ON/OFF" switch and the Electronic Ignition Module 11/2/01 djt (Fig. 19) or the thermopile and the gas valve (Fig. 20). NV360/580 Series Wire Terminal FP1160...
  • Page 14 NV360/580 Series BLACK WHITE BLACK GREEN Fig. 19 Vent Safety Switch wiring, EN/EP units. Vent Safety Switch Fig. 20 RN/RP units using a remote ON/OFF switch. PILOT HONEYWELL S8600 B IGNITION MODULE MVPV SENSE (BURNER) WHITE WHITE BLACK WHITE NOVA SIT 822 VALVE...
  • Page 15: Lighting & Operating Instructions

    3. Open control access panel. 4. Push in gas control knob slightly and turn clock- wise 5. Close control access panel. NV360/580 Series If knob does not pop up when released, stop FP1068 If after several tries, the pilot will not stay lit,...
  • Page 16: Troubleshooting

    NV360/580 Series Honeywell VS8420 Standing Pilot START Gas Supply ON Pilot Lights with Piezo Ignitor Pilot Stays Lit Pilot Lights Main Burner System OK Troubleshooting Remove Glass Panel Before Servicing. CHECK • Supply line hooked up • Shutoff valve open •...
  • Page 17 Clean and/or adjust pilot flame for maximum flame im- pingement on thermopile and thermocouple. Check the vent terminal for blockage (recycling the flue gases). NV360/580 Series CORRECTIVE ACTION...
  • Page 18: Fuel Conversion Instructions

    NV360/580 Series Fuel Conversion Instructions To convert the DV360/580 units for use with a different gas follow these instructions. Before proceeding, turn control knob on valve to “OFF” and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.
  • Page 19: Replacement Of Ceramic Hearth Panels

    Replace shutter retaining screw. For conversion to Natural Gas adjust new air shutters so slots are cov- ered. For conversion to Propane Gas, adjust new air shutters so slots are open. NOTE: NV360 air shutter has only one hole, closed. Secure shutter retaining screws. (Fig. 27) 6.
  • Page 20: Maintenance

    NV360/580 Series Burner and Burner Compartment It is important to keep the burner and the burner com- partment clean. At least once per year the logs and lava rock/ember material should be removed and the burner compartment vacuumed and wiped out. Remove and replace the logs as per the instructions in this manual.
  • Page 21: Replacement Parts

    Volcanic Rock Ember (Package) Lava Rock (Burner) Burner Housing Assembly - Natural Burner Housing Assembly - LP 20003565 21a-d 3565 NV360/580 parts page 12/6/00 djt NV360/580 Series 5a,b 23 a/b 24 a/b NV360 NV580 20002397 20002071 20000376 20000376 51915 51915...
  • Page 22 NV360/580 Series NV360/580 (continued) Ref. Description Ceramic Tile (single) Manifold Assembly Ceramic Hearth Panel (Left) Ceramic Hearth Panel (Right) Ceramic Panel (Rear) 10a. Ceramic Panel (Left Side) 10b. Ceramic Panel (Right Side) Glass with Gasket Gasket Glass Door Frame Assembly...
  • Page 23 Fuel Conversion Kits Conversion Kit, NG to LP NV360RN KIt # 20003896 NV580RN Kit # 20003898 Conversion Kit, LP to NG NV360RP Kit # 20003895 NV580RP Kit # 20003897 20003565 NV360/580 Series NV360 NV580 20000062 20000062 10002013 10002013 10001006 10001006 10001007...
  • Page 24: Accessories

    NV360/580 Series Fan Kits FK12 Fan Assembly 1. Open louvre assembly bottom. 2. Install FK12 fan in back of unit between hearth sup- ports. (Fig. 32) 3. Secure fan on velcro strips. 4. Power to the fan can be supplied by plugging the supply lead into a conveniently located wall socket or by using a hard-wired EB-1 connector box.
  • Page 25 fireplace. Refer to installation instructions provided with the Outside Air Kit. H101a Heat Shield Screws Side View Section A H103 NV360/580 Series Rear Ceramic Panel Back of Firebox Rear Log Support Decorative Frame Trims H102 rear ceramic support...
  • Page 26 NV360/580 Series 20003565...
  • Page 27: Warranty

    PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/ Stove is free from manufacturing and material defects for a period of one year from the date of purchase, subject to the following conditions...
  • Page 28 CFM Corporation 2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www.cfmcorp.com...