Programming; Programming Keys; Quick Set-Up; Acquisition Of The Opening And Closing Positions - Nice SN6011 Instructions And Warnings For Installation And Use

Table of Contents

Advertisement

7

PROGRAMMING

7.1 - Programming keys

A number of programmable functions are available on the SPIN control unit; they can be adjusted using 4 keys on the control unit and are dis-
played with 4 LEDs: L1, L2, L3, R.
The default settings should satisfy most requirements, but can be modified at any time using the appropriate programming procedure; see
Paragraph 7.6.
Buttons
Function
The "OPEN" key enables the user to open the door or scroll up through the programming
Open
s
steps.
Stop /
The "STOP" button can be used to stop the manoeuvre; if pressed for more than 3 sec-
Set
onds, it allows for entering the programming mode, as described below.
The "CLOSE" key enables the user to close the door or scroll down through the program-
Close
t
ming steps.
Radio
The "RADIO" key allows for memorising and deleting the transmitters to be used with
SPIN.

7.2 - QUICK SET-UP

The "Quick set-up" function allows for speeding up the motor's commissioning. It only works with an empty memory.
This procedure allows for detecting and memorising the STOP input configuration, the presence or absence of the connection in "Phototest"
mode of the PHOTO input, the opening and closing positions and the transmitter (if present) memorised in Mode 2 with the Step-by-Step
control.
01.
Make sure that the carriage is attached to the door and is partially open
02.
Power the control unit through the mains and wait 10 seconds
03.
Press and release s
04.
Device recognition phase:
LEDs L2 and L3 flash rapidly for the entire duration of the recognition phase
and the door performs the opening, closing and closing manoeuvres
05.
LED L4(R) flashes once every second: press and release after 5 seconds the
key of the transmitter to be memorised
If the memorisation procedure was successful, LED L4(R) on the control unit
will flash 3 times.
Repeat the procedure for each transmitter to be memorised.
The memorisation phase terminates if nothing is memorised for 10 seconds.

7.3 - Acquisition of the opening and closing positions

The control unit must acquire the opening and closing positions of the door. In this phase, the door stroke from the closing mechanical stop
to the opening mechanical stop is detected. Besides the positions, the STOP input configuration is detected and memorised in this phase,
in addition to the presence or absence of the connection in "Phototest" mode of the PHOTO input.
01.
Ensure that the drive belt/chain is correctly tensioned and that the two mechanical stops are fully secured
02.
Attach the motor carriage
03.
Simultaneously press and hold the Close t and Set keys
04.
When the manoeuvre starts (after roughly 3 seconds), release the keys
Table 7 - Quick set-up procedure
10 s
L2 and L3
L4(R)
...
L4(R)
English – 15