GENERAL SAFETY WARNINGS AND ENGLISH PRECAUTIONS Translation of the original document Warning! Important safety instructions. Follow all instructions as improper installation may cause serious damage. Warning! Important safety instructions. It is important to comply with CONTENTS these instructions to ensure personal safety. Keep these instructions. •...
TN2020LR10* Irreversible gearmotor and courtesy light. To be used as “Slave” of TN2010L or TN2020L * If used in other configurations, ensure that the power supply is from a very low voltage safety system in which voltages never exceed the established low voltage safety limits.
Maximum no. consecutive cycles until 120 120÷180 180÷220 Table 4 - Limits in relation to the force required to move the leaf with 1 TN2010L + 1 TN2020L Force required to move leaf (N) Maximum cycles per hour Maximum no. consecutive cycles until 150 150÷250...
“Figure 4” shows an example of an automation system, produced When laying the ducting for routing the electrical cables using Nice components. and for the cable entry point into the control unit housing, check that there are no water deposits in the junction wells or condensate in the connection ducts.
If programmed as “flashing light” the “FLASH” output can be connected connect the mains power cable directly to terminals 1(phase) and to a NICE “LUCY B” MLB or MLBT flashing light with a 12V 21W car type 2 (neutral), and 3 (earth); secure the cable with the collar.
-30% ÷ +50% with maximum available current of 100mA. SECOND MOTOR ELECTRICAL CONNECTION When the installation involves the use of 2 motors, a TN2010L and a TN2020L, the electrical connection to the second motor must be made as described below.
The automation movement is allowed only between 5% If none of these conditions occur, disconnect the power and 95% of the nominal range. If the position of the auto- supply immediately and check the electrical connections mation is outside this range, the control unit will signal an thoroughly.
17. Press for 2 seconds to confirm position FCC. Led L8 remains lit. 18. On release of all leds turn off. 19. The courtesy light will start flashing once every second to signal the need to run the mandatory “Automatic Force Search” procedure 20.
(min. height 60 mm). manuals, guides and filled out forms. See also: www.nice-ser- vice.com. PROGRAMMING The TEN control unit is equipped with a number of programmable functions; these functions are factory-set to a configuration that should satisfy most automations.
This function allows for managing the movement with a single or double motor: Function ENABLED: must be activated when the installation requires the use of 2 motors (TN2010L + TN2020L) Function DISABLED: must be used when the installation requires the use of a single motor During normal operation of TEN, i.e.
Page 12
Table 9 - List of programmable functions: Level 2 Entry Led Parameter Led (level)) Value Description 10 seconds 20 seconds 40 seconds Adjusts the pause time, i.e. time 60 seconds before automatic closure. L1 * Pause Time Is effective only if automatic clo- 80 seconds sure is enabled 120 seconds...
Result of 1 manoeuvre (the most recent) Result of 2 manoeuvre Allows for viewing the type of Result of 3 manoeuvre faults occurring in the last 8 ma- noeuvres (see Paragraph “8.2 Result of 4 manoeuvre Fault log list”). Fault log list Result of 5 manoeuvre (This is a read-only parameter,...
CHECK OF NUMBER OF MANOEUVRES PERFORMED The function “Maintenance notification” enables the user to check the number of manoeuvres performed as a percentage of the set limit. To check, proceed as follows: Press and hold for approx. 3s Release the key when led L1 starts to flash Press keys ...
Oview programmer instruction manual; or in the web- site www.niceforyou.com. 7.4 - BUFFER BATTERY Fit the PS334 below the TN2010L Pass the battery cable through the TEN cable inlet. RADIO RECEIVER The control unit is equipped with an SM connector for optional SMXI, SMXIS or OXI radio receivers to enable the user to control TEN remo- tely.
To make this estimate, the total of all the gravity ratings in Table 13 must be calculated, for subsequent verification of the estimated feasibility in the graph. For example, TN2010L on a door of 130 Kg, which requires a force of 180Nm to move the leaf, equipped with photocells and no other factors of fatigue, obtains a gravity rating of 60% (30+20+10).
WHAT TO DO IF... (Troubleshooting guide) Certain devices directly provide special signals that help to describe the operating status or any malfunction. If a flashing light is connected it emits one flash per second during the manoeuvre; in the event of faults, the flashing frequency increases with flashes repeated twice, separated by a pause of a second.
Page 18
STOP led (red) Cause ACTION STOP input activation Check the devices connected to the STOP input All OK STOP input active SbS led Cause ACTION All OK SbS input not active SbS input activation Normal if the device connected to the SbS input is effectively active. OPEN led Cause ACTION...
L8 led Description During normal operation indicates that the installation is with 1 motor. During normal operation indicates that the installation is with 2 motors. Flashing • Function programming in progress • With the motor stationary, if it flashes individually it means that the encoder is in the Low Overrun position (position below or equal to 5%).
MAINTENANCE PRODUCT DISPOSAL To ensure constant safety levels a long service life, the system must be serviced regularly. This product constitutes an integral part of the automa- Maintenance operations must be performed in strict com- tion and, therefore, must be disposed of together with it. pliance with the safety precautions provided in this manual and according to the applicable laws and regulations.
TECHNICAL SPECIFICATIONS For purposes of product improvements, Nice S.p.a. reserves the right to apply modifications to technical specifications at any time when deemed necessary, while maintaining the same functionalities and intended use. All technical specifications stated in this section refer to an ambient temperature of 20°C (± 5°C).
“partly completed machinery” Note - The contents of this declaration correspond to that stated in the official document filed in the offices of Nice S.p.A. and, in particular, the latest version thereof available prior to the printing of this manual. The text herein has been re-edited for editorial purposes. A copy of the original declaration can be requested from Nice S.p.A.
Nice products, your installer will certainly find the ideal product for your requirements. However, Nice is not the manufacturer of your automation, which is the result of careful analysis, assessment, choice of materials and the set-up of a system by your entrusted installer.
Page 24
Satisfied? Should you wish to add a new automation system to your home, contact both your local installer and Nice to guarantee specialist consultancy and state-of-the art products on the market, for optimal operation and maximum compatibility of automations.