IndraControl VEH 30.1
Type of
Operator
malfunction
terminal
No enabling
OK
possible
Enabling only
OK
possible on the
left side
Enabling only
OK
possible on the
right side
Connector
cannot be
plugged in
The IndraControl VEH 30.1 does not contain any components to be
maintained by the operator. The housing must not be opened for
maintenance purposes.
Malfunctions that are not mentioned in the following table require a check
of the device at the manufacturer.
Enabling
pushbutton
left
No reaction
OK
Defective
-
-
Fig. 8-1:
Error table of the IndraControl VEH 30.1
Enabling
Possible cause
pushbutton
right
No reaction
Pushbutton
mechanically
damaged
Cable damaged
Defective
XOR operation,
the pushbutton
gets stuck
Internal mechanics
damaged
OK
XOR operation,
the pushbutton
gets stuck.
Internal mechanics
damaged
-
Wrong connector
orientation
Wrong cable
coupling
Plug-pins
damaged
IndraControl VEH 30.1
Measure
Use new device
Use new cable
and/or device
Relieve the left
pushbutton, retry
Otherwise, use
new device
Relieve the right
pushbutton, retry
Otherwise, use
new device
Turn correctly
Use appropriate
cable
Replace
device/cable
DOK-SUPPL*-VEH*30.1***-PR02-EN-P