Maintenance and Installation

8.1

General Information

Maintenance
CAUTION
8.2

LCD Display

8.3

Maintenance of the IndraControl VEH 30.1

8.4
Measures in Case of Malfunctions at the IndraCon‐
trol VEH 30.1
Type of malfunc‐
Operator
tion
terminal
No enabling pos‐
OK
sible
The Embedded Terminals are maintenance-free. However, some components
are subject to wear and must be replaced.
Include the following measures in the maintenance schedule:
The screen is to be cleaned at least once a week using an antistatic fabric
or a cleansing agent containing alcohol.
The surface of the foil as well as the display cover are dissolved by
solvents!
No solvents (e. g. dilution) are to be used!
At least once a year, all plug and terminal connections must be checked
regarding proper tightness and possible damage.
Check that cables are not broken or crushed. Damaged parts must be
replaced immediately.
A fading backlight causes a progressive deterioration of the LCD display's
readability, so that a backlight exchange is required. For further information,
please contact the Bosch Rexroth Service.
The IndraControl VEH 30.1 is designed for the use in the industrial environment.
No special maintenance is required.
We recommend to keep the device away from humidity, oils and emulsions. If
from the ergonomic point of view a particular degree of fouling is achieved the
IndraControl VEH 30.1 has to be cleaned with a smooth, dry and fuzz-free cloth
to restore e. g. the full grip.
The IndraControl VEH 30.1 does not contain any components to be maintained
by the operator. The housing must not be opened for maintenance purposes.
The following table contains different tpyes of malfunctions, possible causes
and remedies.
Malfunctions that are not mentioned in the table require a check of the device
at the manufacturer.
Enabling pushbut‐
Enabling pushbut‐
ton, left
ton, right
No reaction
No reaction
Electric Drives
| Bosch Rexroth AG
and Controls
Maintenance and Installation
Possible cause
Measure
Pushbutton mechanical‐
Use new device
ly damaged
Cable is damaged
Use a new cable or a
new device
45/68