Example(2) Single RAMP+SOAK_B (ALD3=9 + ALD1=19)
Boot completed, the alarm1 is OFF, SV rise 5.00°C rise per minute. when the PV reaches 100 °C, the temperature is kept
for 10 minutes. after 10 minutes alarm is turned ON and the control function keep ON
Parameter setting
Level
Parameter
1
SV
4
SET2.1
4
SET4.1
3
ALD1
3
ALD3
1
SOAK(AL1)
1
RAMP(AL3)
PV time chart
AL1 time chart
Example(3) only use SOAK_A (ALD1=10)
Boot completed, the alarm1 is ON, and the PV is directly controlled at 100 °C. when the PV reaches 100 °C, the temperature is kept
for 10 minutes. after 10 minutes alarm1 and control function are turned OFF
Parameter setting
Level
Parameter
1
SV
3
ALD1
1
SOAK(AL1)
PV time chart
AL1 time chart
51
Set value
100.0
1
1
19
9
0.10
5.00
Temperature
100.0
PV follows SV up 5°C
per minute
ramp start
alarm=ON
25.0
RAMP
5
15 minutes
seconds
Action
ON
OFF
Set value
100.0
10
00.10
Temperature
100.0
Temperature rise
Alarm=ON
25.0
5
seconds
Action
ON
OFF
Description
Target temperature
Display AL3
Display ALD3
AL1 as soak timer
Enable RAMP function
Soak for 10 minutes
5.00°C rise per minute
Time up
Alarm=ON
PV
SOAK
10 minutes
Description
Target temperature
AL1 as soak timer
Soak for 10 minutes
Time up
Alarm=OFF
PV
SOAK
10 minutes
time
time
time
time