Flow Chart Of Parameter Setting; Controlling With Manual Control; Level Operation Mode - Taie FY400 Operation Manual

Digital temperature controller
Hide thumbs Also See for FY400:
Table of Contents

Advertisement

9.8 Controlling With Manual Control

1.
3.
5.

10. Flow Chart of Parameter Setting

10.1 Level Operation Mode

1.
LEVEL 1 enter to the LEVEL 2
Hold SET key for 3 seconds then entering LEVEL 2
2.
LEVEL 1 enter to the LEVEL 3
Hold SET key + SHIFT key for 3 seconds then entering LEVEL 3
3.
LEVEL 2 return to the LEVEL 1
Hold SET key for 3 seconds then return to LEVEL 1
4.
LEVEL 2 enter to the LEVEL 3
Hold SET key for 3 seconds then entering to LEVEL 3
5.
LEVEL 2 enter to the LEVEL 4
On the LEVEL 2 then press SET key to find parameter "LCK
modify LCK value from current value to 1111
after hold SET key + SHIFT key 3 seconds entering LEVEL 4
6.
LEVEL 3 return to the LEVEL 1
Hold SET key + SHIFT key for 3 seconds then return to LEVEL 1
7.
LEVEL 3 return to the LEVEL 2
Hold SET key for 3 seconds then return to LEVEL 2
8.
LEVEL 4 return to the LEVEL 1
Hold SET key + SHIFT key for 3 seconds then return to LEVEL 1
9.
LEVEL 4 return to the LEVEL 2
Hold SET key for 3 seconds then return to LEVEL 2
FY operation manual
Display after power-on.
When
key is pressed,
the lower display flashes.
Press
key to store new
value.
2.
4.
In manual mode OUTL=100.0 , output=100.0 %
continuously.
In manual mode OUTL=20.0 , output=20.0 % continuously.
Hold
2 seconds.
Press
key and
key to set the intended
output% value.
26