Advertisement

PR-8935 Pro Stage 150 RGBW 19°
PR-8936 Pro Stage 150 RGBW 26°
PR-8937 Pro Stage 150 RGBW 5°
PR-8938 Pro Stage 150 RGBW 10°
This product manual contains important information about the safe installation and use of this unit. Please
read and follow these instructions carefully and keep this manual in a safe place for future reference.
PR LIGHTING LTD.
http://www.pr-lighting.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pro Stage 150 RGBW 19 and is the answer not in the manual?

Questions and answers

Summary of Contents for PR Lighting Pro Stage 150 RGBW 19

  • Page 1 PR-8935 Pro Stage 150 RGBW 19° PR-8936 Pro Stage 150 RGBW 26° PR-8937 Pro Stage 150 RGBW 5° PR-8938 Pro Stage 150 RGBW 10° This product manual contains important information about the safe installation and use of this unit. Please read and follow these instructions carefully and keep this manual in a safe place for future reference.
  • Page 2 INDEX ………………………………………………………………………………………… SAFE USAGE OF THE UNIT ………………………………………………………………………………………………… IN STALLING THE UNIT …………………………………………………………………………………………… CONTROL CONNECTION ………………………………………………………………………………………………… DMX TERMINATOR ………………………………………………………………………………………………… OPERATION MENU …………………………………………………………………………………………………… DMX PROTOCOL ……………………………………………………………………………… INDICATION OF LED DIGITAL TUBE ………………………………………………………………………… SETUP OPTIONS-UNIT CONFIGURATION ……………………………………………………………………………………………………… MAINTENANCE ………………………………………………………………………………………………… TROUBLESHOOTING …………………………………………………………………………………………………… TECHNICAL DATA ……………………………………………………………………………………………………………………...
  • Page 3: Safe Usage Of The Unit

    SAFE USAGE OF THE UNIT When unpacking and before disposing of the carton, check there is no transportation damage before using the unit. Should there be any damage caused by transportation, consult your dealer and do not use the apparatus. The unit can be only used indoors, IP20.
  • Page 4: Install The Unit

    INSTALL THE UNIT Mounting Bar Tighten Lens Zoom Knob x2 Clampx1 Color Filter Retainer x1 Yokex1 Safety Cordx1 Tighten Body Knobx2 Lens Tubex1 Shutter Barrelx1 Yoke Locking Knobx2 Yoke Boltx2 Bodyx1 一. Fixture installation: 1.The unit works while being hung, but not suitable for being hung by its side. It can be manually rotated within 90° ; To adjust the fixture’s angle, loosen the Yoke locking knob and move the fixture to the angle desired.
  • Page 5 3. Optional Lens tubes for different beam angles: 19° 26° 5° 10° 三. Installation of Shutter Barrel, replacement of lens Tube and adjustment of Focal Length Tighten Body Knobx2 Shutter Barrel x1 Tighten Zoom Lens Knobx2 Lens Tubex1 1.Adjustment of Lens Tube: loosen the Zoom Lens Knob till the Lens Tube can move along the fixture’s axis, but not let the knob be removed easily;...
  • Page 6: Control Connection

    CONTROL CONNECTION Connection between the controller and a unit and between one unit and another must be made with a 2 core-screened cable, with each core having at least a 0.5mm diameter. Please use the unit’s cannon 5- pin signal input and output cables as connection. The 5-pin signal connections are connected as shown in the figure above.
  • Page 7 Operations Menu level menu level menu level menu Remarks DMX Address 001 - 512 DMX Address Config Setup Color Mode R:000-255 G: 000-255 B: 000-255 W: 000-255 Fade Mode 1-10 1: fastest; 10: slowest Color Offset 128-255 Green 128-255 Blue 128-255 LCD Light Setup No-Yes...
  • Page 8: Dmx Protocol

    DMX PROTOCOL CHANNEL FUNCTION DESCRIPTION Dimmer 000-255 From dark to bright 000 - 007 NO strobe Strobe 008 - 255 Strobe speed from slow to fast 000-255 CT Adjustment 000-016 017-024 White(CT 10000K) 025-032 White(CT 7200K) 033-040 White(CT 5600K) 041-048 White(CT 3200K) 049-056 Cyan...
  • Page 9: Setup Options-Unit Configuration

    SETUP OPTIONS-UNIT CONFIGURATION Explanations for Control Panel After power-on, LCD display displays the company’s LOGO “PR”, then the fixture is at initial display status showing information about company’s name including LOGO “PR”, fixture’s model and DMX address( if the start address is 001, it displays as “address=001”) and at the same time the display is locked.
  • Page 10: Maintenance

    LED Temperature, Fixture Time and Software Version. Press ENTER if the information is desired. FUNC to go back to the upper level menu. Press the button 4. Test Mode While the display is locked(initial display status),Press ENTER button for more than 3s to unlock it, then press the button of DOWN or UP till the menu TEST MODE appears, press ENTER button to enter into its submenus.
  • Page 11: Technical Data

    TECHNICAL DATA VOLTAGES: 100V-240V AC,50/60Hz Power Factor: PF≥0.90 POWER CONSUMPTION: 150W@220V LED: Power consumption 150W Quantity Manufacturers Rated LED Life 50000 Hours COLOUR TEMPERATURE: Linear Adjustment between 2700K and 10000K Luminous Flux: PR-8935(19° ): 1920 lm PR-8936(26° ): 2500 lm PR-8937(5°...
  • Page 12 SIZE PR-8935/PR-8936 SIZES for PR-8937 SIZE for PR-8938 SIZE for 12/16...
  • Page 13: Light Output

    LIGHT OUTPUT PR-8935 (19°) Light Output for PR-8936( 26°) Light Output for 13/16...
  • Page 14 PR-8937(5°) Light Output for PR-8938(10°) Light Output for 14/16...
  • Page 15: Electrical Diagram

    ELECTRICAL DIAGRAM COMPONENT ORDER CODES NAME PART NO. REMARK SIGNAL CABLE 230090003 POWER SWITCH 192010190 MASTER BOARD OF PR-8935 230060485 LED LIGHTSOURCE OF PR-8935 150020299 DRIVER BOARD OF PR-8935 230060486 19° LENS TUBE 120110741 26° LENS TUBE 120110742 5° LENS TUBE 12010751 10°...
  • Page 16 PR LIGHTING LTD. PR New Hi-tech Science Park, 1582 Xingye Avenue Nancun Panyu, Guangzhou, 511442 China TEL: +86-20-3995 2888 FAX: +86-20-3995 2330 P/N:320020341 Version: 20150818 16/16...

Table of Contents