2.3.2 Serial Port
Serial port 1 to 4 (COM 1 to 4) can be configured for RS-232, RS-422, or RS-
485 with auto flow control communication. The default definition of COM 1 and
COM 2 is RS-232, if you want to change to RS-422 or RS-485, you can find the
setting in BIOS.
BIOS Setting
COM 1
COM 2
COM 3
COM 4
The pin assignments are listed in the table as follows :
Serial
Port
1, 2
3, 4
©Vecow ABP-3000 User Manual
RS-232
RS-422 (5-wire)
RS-422 (9-wire)
RS-485
RS-485 w/z auto-flow control
Pin No.
RS-232
1
DCD
2
RXD
3
TXD
4
DTR
5
GND
6
DSR
7
RTS
8
CTS
9
RI
Function
RS-422
RS-422
(5-wire)
(9-wire)
TXD-
TXD-
TXD+
TXD+
RXD+
RXD+
RXD-
RXD-
GND
GND
-----------
RTS-
-----------
RTS+
-----------
CTS+
-----------
CTS-
GETTING TO KNOW YOUR ABP-3000
RS-485
(3-wire)
DATA-
DATA+
-----------
-----------
GND
-----------
-----------
-----------
-----------
14