Machine Settings - RoboLabs ROBOSUGAR CPA-10 Operation Manual

Table of Contents

Advertisement

ROBOSUGAR CPA-10(A) Sep-18
6

2.8 MACHINE SETTINGS

Some aspects of machine operation may be adjusted. To adjust settings
do the following:
Turn the machine off, then press and hold HEATING and COOLING
pushbuttons together and turn the main switch in ON position. You will
see flashing buttons and hear buzzer signals.
Default values are the following:
1 – mixing frequency during heating stage – 5 s;
2 – mixing stage duration – 90 s;
3 – cooling stage duration – 300 s.
Buttons are flashing in cyclic way. Count of flashes per single cycle
points current value:
Frequency of mixing
Duration of mixing
Duration of cooling process
in heating stage
in mixing stage
Thus, with default settings, HEATING, MIXING, COOLING backlights
are flashing 2, 3 and 5 times per cycle, respectively.
To adjust any value, corresponding button must be pressed. Each
stroke increases the value by one point. Once maximum value is
reached, further stroke will set minimum value.
For example, let's suppose that cooling time should be changed from
300s to 240s. Pressing COOLING button four times we'll make changes
like this: 360s – 120s – 180s – 240s.
To exit adjustment mode and save the changes, turn the machine off.
6
Applicable for machines with s/n starting with 1338.215.04.164.
12