inVENTer Pulsar Installation And Operating Instructions Manual

inVENTer Pulsar Installation And Operating Instructions Manual

Extractor fan

Advertisement

Quick Links

Extractor fan
Pulsar
Installation and operating instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pulsar and is the answer not in the manual?

Questions and answers

Summary of Contents for inVENTer Pulsar

  • Page 1 Extractor fan Pulsar Installation and operating instructions...
  • Page 2: Table Of Contents

    The copyright of this document remains with the manufacturer. 3.2 Dimensions ............9 3.3 Dimensional drawing ..........9 10 Delivery ...............33 Rights to all contents and images: © inVENTer GmbH 2016-20. 4 Elektrical connections ..........10 11 Accessories ..............33 All trademarks used in this document are the property of their respective 4.1 Electrical connection 100 –...
  • Page 3: User And Safety Instructions 6 Commissioning

    Thank you for purchasing this high quality product from inVENTer! This section provides an overview of the basic safety The Pulsar extractor fan is designed to ventilate rooms procedures.
  • Page 4: System Overview

    This must not contain any obstructions or other rooms in accordance with VDE 0100 If required, the Pulsar extractor fan can also be used as a • Boost function objects that interfere with the airflow.In order to prevent •...
  • Page 5: Preparing For Installation

    Wall sleeves are available in the aV100 wall installation set including weather protection hood, from inVENTer GmbH. A power supply unit is required for the 12 V DC connection. PSU and flush-mounted (plasterboard) box are available from inVENTer GmbH. ...
  • Page 6 Electric shock and injury due to live components (230 V, 50 Hz)! ►Before working on electrical installations, disconnect all affected equipment from the power supply. Figure 5: PCB of Pulsar extractor fan: Terminal assignment for power cable connecting terminal (230 V AC) ►Do not lay or connect live cables.
  • Page 7 • When the fan is switched off at the external S switch, the fan switches off immediately. DC 12 V Figure 7: Wiring diagram for Pulsar extractor fan 230 V AC, switch-controlled, without run-on function 5 Switch-controlled, with run-on function: •...
  • Page 8: Electrical Connection 12 V Dc

    DANGER Ingress of water into the power supply unit. TIP: The S1 switch integrated into the Pulsar extractor fan does not work with a 12 V DC connection. Electric shock and overheating due to short circuit (230V, 50Hz)! ►Install power supply unit outside protection areas 0 to 2.
  • Page 9: Installation

    TIP: The aV100 wall installation set (wall sleeve including back-draught shutter and exterior closure), into which the Pulsar extractor fan can be inserted, is available as an option from inVENTer GmbH. Creating the wall opening and installing the wall sleeve ►...
  • Page 10 DANGER  The flush-mounted box for the power supply unit Ingress of water into the Pulsar extractor fan. has been fitted. Electric shock and overheating due to short circuit (230V, 50Hz)! ►Create the wall opening for the power supply unit outside protection area 2.
  • Page 11: Inserting And Connecting The Pulsar Extractor Fan

    INSTALLATION INSTALLATION Inserting and connecting the Pulsar extractor fan ► Lift the cover of the fan casing forwards from the top. Screw driver, drilling machine, rawl plugs, screws, spirit level, wire stripping tool Requirements: The wall sleeve is mounted and any protective discs have been removed.
  • Page 12 This ensures that the cables do not interfere with the ► Remove the casing from the wall sleeve and drill the holes. installation of the fan unit and prevents malfunctions of the extractor fan. DC 12 V Pulsar extractor fan • Installation and operating instructions Pulsar extractor fan •...
  • Page 13: Installing The Fan Casing's Cover And Fan Unit

    (red arrow) on the fan casing's base plate. Ensure that the lock button (red arrow) clicks into place between the guides for the fan unit. −  The Pulsar extractor fan is inserted and the voltage cable is connected. Pulsar extractor fan • Installation and operating instructions Pulsar extractor fan •...
  • Page 14 Direct pairing with Bluetooth Smart leads to installation errors and the Pulsar must be de-installed (Before reset, deactivate the Auto pairing function in Bluetooth Smart!). Different functions and settings are available within the app depending on the electrical connection of the Pulsar extractor fan. Requirements for app functionality: ►...
  • Page 15 Pulsar: device. • At any given time, the Pulsar can only be operated from A blue LED on the fan unit of the Pulsar extractor fan indi- Configuration of: one mobile device. Simultaneous control of the same cates that an active Bluetooth Smart connection to a mobile •...
  • Page 16 The power supply is disconnected. DANGER 230 V AC: Disconnect the switch on the Pulsar extractor fan. The switch is located on the left side of the fan casing. Exposed electrical components and rotating parts on the fan. Push it down into position 0.
  • Page 17 SPECIFICATIONS SPECIFICATIONS Specifications Air flow characteristic of Pulsar extractor fan Pulsar extractor fan Feature Value Protection class Type of protection IP44 Input voltage 100 – 240 V AC or 12 V DC Extract air flow rate (free blowing) [m³/h] Power consumption [W] Noise emission (rated) [dB(A)] 17 –...
  • Page 18 COMPANY DETAILS Technical customer service InVENTer GmbH provides a five-year guarantee for the PUBLISHER: Pulsar extractor fan. This covers premature product wear. INVENTER GMBH For technical support contact our service staff. ORTSSTRASSE 4A Further information about the warranty is available at D-07751 LÖBERSCHÜTZ...
  • Page 19 PIN code / serial number Important! To activate the inVENTer Mobile app, enter the PIN code or scan it with your phone. You can also find your specific PIN code on the right foot of the fan unit. inVENTer GmbH Ortsstraße 4a...

Table of Contents