  • Page 1 Installation and operating instructions...
  • Page 2: Table Of Contents

    Fitting the inner cover ...................... 27 The copyright of this document remains with the manufacturer. Operation of the iV-Compact ventilation unit ............... 29 Rights to all contents and images: © inVENTer GmbH 2014-19. Opening/closing the inner cover ..................29 Tilting the inner cover ....................... 29 All trademarks used in this document are the property of their respective manufacturers and are hereby acknowledged.
  • Page 3: User And Safety Instructions

    The safety and warning instructions in these operating instructions have a uniform structure The inVENTer ventilation units with heat recovery are used to ventilate living rooms and living and are marked with a symbol on the left side of the instruction. A signal word in front of the text spaces.
  • Page 4 • 2011/65/EC: RoHS • Never use the unit without the filters and inner cover. • Use the sMove controllers exclusively to control inVENTer ventilation units with heat recovery • Before performing cleaning or maintenance tasks, disconnect the controller's power supply and put on gloves. iV-Compact ventilation system •...
  • Page 5: System Overview

    It is suitable for installation in new buildings as well as for retrofitting in existing buildings. Installation is carried out in the exterior wall. The ventilation unit iV-Compact comprises a wall sleeve into which a thermal accumulator insert is installed. A closable inner cover conceals the ventilation unit visually discreet on the interior wall side. On the exterior wall a driving rain proof hood covers the unit.
  • Page 6: Function

    SYSTEM OVERVIEW SYSTEM OVERVIEW Function Control elements The iV-Compact ventilation system is used to provide ventilation for living rooms and bedrooms. sMove controller An integrated thermal accumulator in combination with the Xenion reversible fan and the guiding vanes ensures optimum heat recovery with maximum air flow. The controllers from the sMove product range are electronic control units The ventilation unit operates on the principle of heat re- for controlling the iV-Compact ventilation units.
  • Page 7: Preparing For Installation

    1 between two ventilation units in push-pull operation (pair) in the same room to avoid the 1,4 m mixing of outdoor air and exhaust air: Figure 2: Dimension drawing: wall opening iV-Compact (Interior view) 1 Wall opening (fig. 2, left) 3 Door/window reveal Horizontal or vertical installation Installation with height offset: Simplex installation system (fig. 2, right)
  • Page 8: Sectional Drawing

    3 Fastening screws for cover (4 x) 6 Guidance for fastening screws (4 x) 4 Bottom drip rail 7 Protective grid Flair inner cover Figure 3: Sectional drawing iV-Compact (side view) A - A A Inner plaster/internal structure C Render B Masonry 1 Inner cover base plate incl. filter...
  • Page 9: Installation And Assembly

    Ø NOTE Condenstae collecting in the wall sleeve leads to damage to the exterior wall Figure 6: Standard components of ventilation unit iV-Compact and masonry! 1 Compact Protective hood 3 c: Xenion reversible fan • Create wall opening at a slope of 1 – 2° to...
  • Page 10: Laying The Fan-Bus

    Cable: Strands, 3-wire, max. length 33 m pairs Ventilation unit Connecting The fan-BUS (controller cable) is laid.  Ö Switching Control unit Operated in terminals pairs iV-Compact ventilation system • Installation and operating instructions iV-Compact ventilation system • Installation and operating instructions...
  • Page 11: Fitting The Wall Sleeve

    ► Route the controller cable through the recess into mounting wedges until they are flush with the the wall sleeve. external and interior wall. Be careful not to damage the controller cable. The wall sleeve is fitted.  Ö iV-Compact ventilation system • Installation and operating instructions iV-Compact ventilation system • Installation and operating instructions...
  • Page 12: Installing The Weather Protection Hood

    ► Align the base plate using a spirit level. ► Mark out the four bore holes for fastening the base plate. The weather protection hood is installed.  Ö iV-Compact ventilation system • Installation and operating instructions iV-Compact ventilation system • Installation and operating instructions...
  • Page 13: Installing The Thermal Accumulator Insert And Connect The Fan To The Controller

    • Observe the correct cable colour sequence at the socket and plug. If the colour sequence is same direction. wrong, the fans will not start. The functional test has been performed.  Ö iV-Compact ventilation system • Installation and operating instructions iV-Compact ventilation system • Installation and operating instructions...
  • Page 14: Starting The Ventilation Systemn

    White CCW (–) Black TIP: When looking from the side, the plug-in connection forms an "S" like "Supply" when in starting direction Supply air. iV-Compact ventilation system • Installation and operating instructions iV-Compact ventilation system • Installation and operating instructions...
  • Page 15: Opening/Closing The Inner Cover

    ► Place the cover on the four spacers. Voraussetzung: Die Innenblende ist geöffnet. Make sure that the marking arrows on the cover's rear side are pointing to the top (inVENTer logo on ► Slide the inner cover panel onto the lower (upper) cover's front is located on the bottom right).
  • Page 16: Cleaning And Maintenance

    To clean and maintain the ventilation unit, first remove the panel of the inner cover. Recommended maintenance Requirements: The ventilation unit is switched off. The maintenance tasks and intervals listed here are recommended by inVENTer GmbH to maintain the functionality and performance of the iV-Compact ventilation system. ► Open the inner cover ( 5.1). Depending on requirements and/or air quality, your personal maintenance plan may deviate ►...
  • Page 17: Cleaning/Replacing Dust Filters

    You have removed the thermal accumulator insert. Ö ► Place the cover on the four spacers. Ensure that the inVENTer logo is located on the bottom right. ► Press the side detent lugs inwards on the inner cover base plate's spacers.
  • Page 18: Cleaning And Reassembling The Thermal Accumulator Insert

     6.2, page 32. Remove the remaining guiding vane as previ-  Ö ously described. You have cleaned and re-installed the thermal  Ö accumulator insert. iV-Compact ventilation system • Installation and operating instructions iV-Compact ventilation system • Installation and operating instructions...
  • Page 19: Label According To Ec Directive For Energy Related Products

    Wall opening [mm] Ø 180 Wall sleeve Ø 160 Conformity ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI 2016 1254/2014 iV-Compact ventilation system • Installation and operating instructions iV-Compact ventilation system • Installation and operating instructions...
  • Page 20 SPECIFICATIONS SPECIFICATIONS Specifications according to EC Directive for energy related products, regulation 1254/2014 [Germany] iV-Compact, local demand control: iV-Compact, manual control: Product fiche iV-Compact according to VO 1254/2014 EU, dated 2014-07-11 Product fiche iV-Compact according to VO 1254/2014 EU, dated 2014-07-11 Description Data Description Data Supplier's name inVENTer GmbH Supplier's name inVENTer GmbH Supplier's model identifier iV-Compact Supplier's model identifier iV-Compact cold -81.498 cold -72.195 SEC class / Specific energy con- SEC class / Specific energy con- average -40.735 average -34.715...
  • Page 21 Base plate IC Flair V-233x233 2003-0223 Panel IC Flair V-233x233 2003-0221 Panel IC Flair V-233x233 w/ sound insulation 2003-0222 Spacer for base plate IC, 25mm, white 3006-0151 iV-Compact ventilation system • Installation and operating instructions iV-Compact ventilation system • Installation and operating instructions...
  • Page 22: Troubleshooting And Disposal

    The connector plug must be sitting firmly in the connector housing. The controller is operating in Select heat recovery mode on the con- continuous ventilation mode. troller. iV-Compact ventilation system • Installation and operating instructions iV-Compact ventilation system • Installation and operating instructions...
  • Page 23: Guarantee And Warranty

    Manufacturer guarantee inVENTer GmbH provides a five-year guarantee for all electrical components and the wall sleeve, as well as a thirty-year guarantee on the heat accumulator ceramic. This covers premature product wear. It affects in no way the applicable law. Further information about the warranty is available at www.inventer.eu/warranty Service Claims Check the delivery for completeness and transport damage upon receipt using the delivery note.
  • Page 24 CEO: ANNETT WETTIG VAT ID NUMBER: DE 815494982 JENA DISTRICT COURT HRB 510380 PICTURE CREDITS: Cleaning/ Control measure: Controlled (C) / Cleaned (R) / Changed (W) © INVENTER GMBH 2014-19 Component Designation / Scope Action ALL RIGHTS RESERVED: Inner cover: Cleaning Filter: Check, clean or change if ©...
  • Page 25 GmbH Ortsstraße 4a D-07751 Löberschütz +49 (0) 36427 211-0 +49 (0) 36427 211-113 info@inventer.de Version dated 04/2019 Subject to modifications. Item number: 5006-0005 www.inventer.eu © inVENTer GmbH 2014-19...