Saflok Door Unit Inspection Criteria; Appearance; Lock Function; Electronics/Keycards - Kaba Saflok MT RFID Installation Instructions Manual

Table of Contents

Advertisement

MT
RFID Installation Instructions
TM

SAFLOK Door Unit Inspection Criteria

Appearance

Finish is free of blemishes or scratches that would distract from lock appearance
Lock body and under plate (if used) are mounted straight on the door
Door scalp is mounted straight and flush with the door edge
Jamb strike is mounted straight and is flush with the jamb face
Correction of minor blemishes on the door jamb are the responsibility of the property's maintenance department

Lock Function

Knob or lever rotates and moves freely
Lever is horizontal to floor when at rest position
Dead bolt extends fully and retracts without binding (door open)
Lock latch and dead bolt engage jamb strike plate freely
Anti-pick latch when depressed (door open)
Anti-pick latch is depressed when contact is made with the strike plate (door closed)

Electronics/Keycards

Green light flashes when the proper keycard is used
Green light is flashing when the lever is operated
Green light continues to flash for a five-second cycle
Yellow light flashes 12 times when the dead bolt is extended and a guest/hotel keycard is used
All keycards function to the specifications of the properties key design
Door function
Door closes and latches with little or no interference
Dead bolt extends fully through the strike plate without interference (door closed)
Spacing between door edge and inside door jamb does not exceed 3/16" (door closed)
Note: If bumpers or other seals are added after strike plate installation and causes alignment and latch problems, it
is the property's responsibility to correct this condition. This note generally applies to new construction or new door
installation
Questions? Call Customer Service at 800.999.6213 and select option 3. For online assistance, visit support.saflok.com.
FCC and IC Warnings: This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following
two conditions: (1) this device may not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
© SAFLOK, all rights reserved.