PROMAX-8
4.2.6.1

Datalogger configuration.

From the LOGGER mode,
when pressing the CONFIG key [14]
we will accede to the configuration
menu.
This
menu
THRESHOLD and MEASURES parameters. To
accede to them turn the rotary selector and once
the parameter we want to change is appears
shadowed, press it; then turning it its value will b
validate the new value.
a) THRESHOLD: It activates / deactivates the measurement threshold.
This parameter allows to carry out the logger function in an agile way, by
activating only those measures we consider significative.
In the OFF mode (deactivated) all measurements are taken (with a level
higher than 20 dBμV). On the other hand, when a level is defined, only
those channels with a level higher than the THRESHOLD value will be
measured.
For the digital channels the measurements are only taken if exists a signal
level higher to the defined value by the THRESHOLD parameter (+ 14 dB in
the case of digital channels with a bandwidth of 6 MHz and +15 dB in the
case of digital channels with a bandwidth of 7 and 8 MHz).
b) MEASURES: It defines the types of measurements to be taken.
This parameter allows to select the measurements that are desired to made
between:
- Level
- Lev - V/A - C/N : Level, Video to Audio and Carrier to Noise ratios. V/A
ratio is only performed on analogue channels.
The measurements carried out on CH-FR operating mode are more actual since they
are taken using an integration procedure and they consider the whole channel
spectrum.
To leave the configuration menu of the DATALOGGER mode, just press the key of
the operating mode you wish to access.
09/2013
SE
permits
to
modify
the
Figure 46.- Logger configuration menu.
e modified. Finally press it again to
REMARK
IMPORTANT
Page 39