Wi-Fi device IE-WL-BL-AP-CL
are out of the control room for an extended period, they can still be informed of the status of devices almost
instantaneously when exceptions occur.
In addition to logging these events, the IE-WL-BL-AP-CL supports different approaches to warn engineers
automatically, such as SNMP trap and e-mail.

System Logs

System Log Event Types
All the event group types are shown on this page. Select the event types (groups) that you want to enable by
checking the Enable logging box next to the event types. By default, all event types are enabled (checked).
The system events log can be viewed at Status  System Logs.
System-related events
System warm start
System cold start
Watchdog triggers reboot
Network-related events
LAN link on
LAN link off
Client joined/ left
(for AP/Master mode)
WLAN connected to AP
(for Client/Slave mode)
WLAN disconnected
(for Client/Slave mode)
RSTP changed
RSTP new root bridge ID
Client Roaming from previous AP to
current AP (for Client/Slave mode)
IP address conflict
Link fault pass-through LAN/WLAN
connected because of WLAN/LAN up
Link fault pass-through LAN/WLAN
disconnected because of WLAN/LAN down
Channel availability check over DFS
frequency (for AP/Master mode)
Event is triggered when...
The IE-WL-BL-AP-CL is rebooted, such as when its settings are
changed (IP address, subnet mask, etc.).
The IE-WL-BL-AP-CL is rebooted by power down.
The IE-WL-BL-AP-CL is rebooted by watchdog
Event is triggered when...
The LAN port is connected to a device or network.
The port is disconnected (e.g., the cable is pulled out, or the
opposing device shuts down).
A wireless client is associated or disassociated.
The IE-WL-BL-AP-CL is associated with an AP.
The IE-WL-BL-AP-CL is disassociated from an AP.
The RSTP topology has changed
The RSTP changes its root bridge ID
A client roams from a previous AP to the current AP if the signal
strength of the current AP is greater than the previous AP by a
certain value.
The IE-WL-BL-AP-CL has the same IP address as another device
connected to the same subnet.
The WLAN/LAN link is up and the Link fault pass-through (LFPT)
enables the LAN/WLAN functionality.
The WLAN/LAN link is down and the Link fault pass-through (LFPT)
disables the LAN/WLAN functionality.
The channel availability check (CAC) is started on channel
[channel] at [frequency] GHz for 60 sec./
The channel availability check (CAC) task has been completed on
channel [channel] at [frequency] GHz./
A radar signal is detected on channel [channel] at [frequency]
GHz.