Wi-Fi device IE-WL-BL-AP-CL
SNMP agent version
Setting
V1, V2c, V3, or
V1, V2c, or
V3 only
Admin auth type (for V1, V2c, V3, and V3 only)
Setting
No Auth
MD5
SHA
Admin private key (for V1, V2c, V3, and V3 only)
Setting
Disable
DES
AES
Private Key
A data encryption key is the minimum requirement for data encryption (maximum of 63 characters)
Private MIB Information Device Object ID
Also known as OID, this is IE-WL-BL-AP-CL's enterprise value, which is a fixed value.

Link Fault Pass-Through (for Client mode only)

This function means if Ethernet port is link down, wireless connection will be forced to disconnect. Once
Ethernet link is recovered, IE-WL-BL-AP-CL will try to connect to AP.
If wireless is disconnected, IE-WL-BL-AP-CL restarts auto-negotiation on Ethernet port but always stays in the
link failure state. Once the wireless connection is recovered, the device will try to recover the Ethernet link.
System log will indicate the link fault pass through events in addition to the original link up/down events.
Link Fault Pass-Through
Setting
Enable
Disable

Logs and Notifications

Since industrial-grade devices are often located at the endpoints of a system, these devices will not always
know what is happening elsewhere on the network. This means that these devices, including wireless APs or
clients, must provide system maintainers with real-time alarm messages. Even when system administrators
Description
Select the SNMP protocol version used to manage the switch.
Description
Use admin account to access objects. No authentication
Provide authentication based on the HMAC-MD5 algorithms.
8-character passwords are the minimum requirement for
authentication.
Provides authentication based on
HMAC-SHA algorithms. 8-character passwords are the
minimum requirement for authentication.
Description
No data encryption
DES-based data encryption
AES-based data encryption
Description
Enables Link Fault Pass-Through
Disables Link Fault Pass-Through
3-42
Web Console Configuration
Factory Default
V1, V2c
Factory Default
No Auth
Factory Default
Disable
Factory Default
Disable