12.5 Digital & Analog I/O
Digital Inputs Specification
Voltage Range
Response Time
Analog Inputs Specification
Range
Resolution
Impedance
Accuracy
Scaling & Offset
Analog Output Specification
Range
Resolution
Relay Output
Max Switching
Max Switching
Response Times
Command Source
Digital Input
Analog Input
Modbus RTU Interface
CAN Interface
Master / Slave Function
Power Stage

12.6 Output Current Limit

Overload Operation
EC Titanium provides the following maximum permissible overload current:
• 150% Output current / 60 Seconds Maximum
• 175% Output current / 2.5 Seconds Maximum
Maximum continuous output current and maximum permissible overload time may be adjusted according to the following:
• PWM Switching Frequency Selected
• Low Output Frequency
• High Ambient Temperature
12-2 Technical Data
8 – 30 V dc, Internal or External supply, NPN (positive logic)
< 8ms
Current:
0-20mA, 4-20mA. 20mA max input current
Voltage:
-10-10V (Analog Input 1 Only), 0-10V, 0-5V, 0/24V, 30V max input
Analog Input 1:
12-bit, <16ms response time (Uni-Polar)
Analog Input 2:
12-bit, <16ms response time (Uni-Polar)
Current Mode:
500R
Voltage Mode:
> 100kR
Better than 1% of full scale
Parameter adjustable
Current:
0...20mA, 4...20mA, 20mA max
Analog:
0..10V, 0 / 24V (digital), 20mA max
10-bit
Accuracy
better than 1% of full scale
Voltage:
250VAC, 30 VDC
Current:
5A at 30 Volt DC, 6A at 250 Volt AC
Response Time
<8ms
<16ms
<8ms from receipt of valid command
<8ms from receipt of valid command
<8ms, response, 60ms cycle
<10ms to enable output